Mechanical Evaluation of an Elastomeric Cushion For Total Knee Replacement

dc.contributor.advisorNewcombe, W. R.
dc.contributor.advisorRepo, R. U.
dc.contributor.authorKelly, Brian
dc.contributor.departmentMechanical Engineeringen_US
dc.date.accessioned2019-06-03T15:16:37Z
dc.date.available2019-06-03T15:16:37Z
dc.date.issued1992-05
dc.description.abstractMechanical factors have been cited as a primary cause of total knee replacement failure. A hypothesis has been formulated stating that the introduction of a compliant interface into a total knee prosthesis would moderate excessive stresses and strains, thereby, extending joint life. A biocompatable elastomer developed by the Dow Corning Corporation was selected for mechanical evaluation as a cushioning material. Force-strain, impact, and fatigue tests were conducted on several specially designed and fabricated elastomer test shapes. Test results demonstrate that a suitably stiff and dynamically responsive elastomer cushion can be designed to handle repeated physiological knee joint loads. Physiological impacts with cadaver tibias demonstrated significant shock reduction benefits, including peak force reductions of up to 70%, with the addition of different elastomer shapes. Compressive fatigue evaluation of elastomer samples was inconclusive owing to extensive sample wear. As a result configurations or applications where the elastomer can move relative to a rigid surface are not recommended. A new, mechanically contained elastomer shape was designed and tested which greatly reduced wear. Bonding of this new shape to prosthetic joint materials is recommended for further experimental evaluation.en_US
dc.description.degreeMaster of Engineering (ME)en_US
dc.description.degreetypeThesisen_US
dc.identifier.urihttp://hdl.handle.net/11375/24477
dc.language.isoenen_US
dc.subjectmechanicalen_US
dc.subjectmechanical evaluationen_US
dc.subjectelastomeren_US
dc.subjectelastomericen_US
dc.subjectelastomeric cushionen_US
dc.subjecttotal knee replacementen_US
dc.subjectkneeen_US
dc.subjectknee replacementen_US
dc.subjectcushion for total knee replacementen_US
dc.subjectelastomeric cushion for total knee replacementen_US
dc.subjectelastomer cushion for total knee replacementen_US
dc.subjectmechanical engineeringen_US
dc.subjectengineeringen_US
dc.titleMechanical Evaluation of an Elastomeric Cushion For Total Knee Replacementen_US
dc.title.alternativeMechanical Evaluation of an Elastomer Cushion For Total Knee Replacementen_US
dc.typeThesisen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Kelly_Brian_P_1992May_masters.pdf
Size:
14.46 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.68 KB
Format:
Item-specific license agreed upon to submission
Description: