Welcome to the upgraded MacSphere! We're putting the finishing touches on it; if you notice anything amiss, email macsphere@mcmaster.ca

DEVELOPMENT OF A THICK GAS ELECTRON MULTIPLIER-BASED MULTI-ELEMENT MICRODOSIMETRIC DETECTOR

dc.contributor.advisorByun, Soo-Hyun
dc.contributor.authorAnjomani, Zahra
dc.contributor.departmentMedical Physicsen_US
dc.date.accessioned2017-05-17T17:14:22Z
dc.date.available2017-05-17T17:14:22Z
dc.date.issued2017
dc.description.abstractTissue Equivalent Proportional Counters (TEPCs) are considered the standard instrument for microdosimetry, aiming at measuring the distribution of the energy deposited by ionizing radiation in a micrometric target, and have been employed for a number of radiation physics, radiation protection and radiation biology applications. This study describes development procedure and performance of a novel multi-element TEPC. Following an extensive Geant4 simulation study, an advanced prototype multi-element gaseous microdosimetric detector was developed using the Thick Gas Electron Multiplier (THGEM) technique. The multi-element design was employed to increase the neutron detection efficiency. The prototype THGEM multi-element detector consists of three alternating layers of tissue equivalent plastic hexagons and each layer houses a hexagonal array of seven cylindrical gas cavity elements with equal heights and diameters of 17 mm. The final detector structure incorporates 21 gaseous volumes. Owing to the absence of wire electrodes, the THGEM multi-element detector offers flexible and convenient fabrication in contrast to the traditional wire-based methods. The detector responses to neutron and gamma-ray were investigated using the McMaster Tandetron 7Li(p,n) neutron source. The dosimetric performance of the detector is presented in contrast to the response of a commercial tissue equivalent proportional counter. The collected spectra exhibit the expected features of the lineal energy distributions for given proton beam energies. Compared to the 2 inch TEPC response, the detector gave a consistent microdosimetric response with a maximum discrepancy of 15% in measured neutron absorbed dose. An improvement of a factor of 3.0 in neutron detection efficiency has been accomplished. The prototype detector offers a simple fabrication process and provides the fundamental basis for development of a high efficiency TEPC dedicated for monitoring weak neutron radiation fields.en_US
dc.description.degreeDoctor of Philosophy (PhD)en_US
dc.description.degreetypeThesisen_US
dc.identifier.urihttp://hdl.handle.net/11375/21428
dc.language.isoenen_US
dc.titleDEVELOPMENT OF A THICK GAS ELECTRON MULTIPLIER-BASED MULTI-ELEMENT MICRODOSIMETRIC DETECTORen_US
dc.typeThesisen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Anjomani_Zahra_201704_PhD.pdf
Size:
19.28 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.68 KB
Format:
Item-specific license agreed upon to submission
Description: