INVESTIGATION OF CADMIUM ZINC TELLURIDE DETECTOR FOR MEDICAL IMAGING APPLICATIONS

dc.contributor.advisorDeen, M. Jamal
dc.contributor.authorZheng, Xiaoqing
dc.contributor.departmentElectrical and Computer Engineeringen_US
dc.date.accessioned2019-02-07T14:27:46Z
dc.date.available2019-02-07T14:27:46Z
dc.date.issued2017
dc.description.abstractThe wide band gap semiconductor Cadmium Zinc Telluride (CZT) is of recent interest for medical imaging at room temperature. A number of properties, including superior energy resolution, 3D photon position sensitivity, compact size, direct photon conversion and energy-resolving capability, make CZT a promising candidate for positron emission tomography (PET) and photon-counting X-ray imaging systems. Despite these advantages, drawbacks, such as low mobility of holes, hole trapping, charge sharing effect and characteristic X-ray escape degrade the performance of large volume CZT detectors. In this research, characterization and evaluation of single-crystal CZT photon detector using simulation and experimental studies were done. First, a comprehensive analytical model was developed and implemented by using Monte Carlo simulation and finite element analyses. This model includes the generation and transportation of charge carries within CZT detectors, and it provides useful guidance in optimizing the electrode design and associated readout circuits. Second, the performance of a 20×20×5mm3 CZT crystal with 8×8 pixel anodes and a planar cathode was integrated with readout electronics that can be used to build a PET system was studied. The experiments demonstrate an energy resolution of ~2.26±0.84% full width half maximum (FWHM) at 662 keV and 19±3 ns coincidence time resolution with planar parallel field configuration. A novel algorithm based on charge sharing effect and transient signal analysis targeting the improvement of spatial resolution, was proposed. The sub-pitch spatial resolution is found to be ~30 µm and ~250 µm under signal-to-noise ratio of ~17, for inside and outside the valid range of charge sharing, respectively. Finally, the feasibility of CZT in photon-counting Computed Tomography (CT) was studied by using monoenergetic sources, with a special attention paid to energy degradation due to characteristic X-ray escape and the charge sharing effect. The effects of detector configuration and incident beam location were also investigated. The results show that the pixel size can be reduced to 500 µm without significant count loss (~5%) and charge loss (~15%) for the photo-counting X-ray applications.en_US
dc.description.degreeDoctor of Philosophy (PhD)en_US
dc.description.degreetypeThesisen_US
dc.identifier.urihttp://hdl.handle.net/11375/23880
dc.language.isoenen_US
dc.subjectCZTen_US
dc.subjectMedical Imagingen_US
dc.titleINVESTIGATION OF CADMIUM ZINC TELLURIDE DETECTOR FOR MEDICAL IMAGING APPLICATIONSen_US
dc.typeThesisen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Zheng_Xiaoqing_2017Nov_PHD.pdf
Size:
4.23 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.68 KB
Format:
Item-specific license agreed upon to submission
Description: