Welcome to the upgraded MacSphere! We're putting the finishing touches on it; if you notice anything amiss, email macsphere@mcmaster.ca

2D/3D Registration Algorithm for Lung Brachytherapy

dc.contributor.advisorFarrell, Tomen_US
dc.contributor.advisorHunter, Roberten_US
dc.contributor.advisorWierzbicki, Marcinen_US
dc.contributor.authorZvonarev, Pavelen_US
dc.contributor.departmentMedical Physicsen_US
dc.date.accessioned2014-06-18T17:03:35Z
dc.date.available2014-06-18T17:03:35Z
dc.date.created2013-09-09en_US
dc.date.issued2013-10en_US
dc.description.abstract<p>The typical High Dose Rate (HDR) lung brachytherapy procedure involves inserting treatment catheters into the bronchi next to the tumour location using a bronchoscope. The anterior-posterior and lateral fluoroscopy images are acquired in order to localize the catheters prior to treatment. Although, these images enable accurate reconstruction of the catheter location, they do not allow for the visualization of the tumour or organs-at-risk due to poor soft tissue contrast. Although CT images offer an improved soft tissue contrast, moving the patient with catheters in place prior to each treatment is impractical.</p> <p>An alternative option is to use prior diagnostic or external beam radiation treatment planning CT images. These images cannot be used for treatment planning directly because of the variation in patient positioning between the CT and orthogonal images acquisition. In order to account for positioning differences, a 2D/3D registration algorithm that registers the orthogonal images with a previously acquired CT data was developed. The algorithm utilizes a rigid registration model based on a pixel/voxel intensity matching approach. A similarity measure combining normalized mutual information (NMI), image gradient, and intensity difference was developed. Evaluation of the algorithm was performed using tissue equivalent phantoms, and, in the clinical setting using data from six patients. The mean registration error was 2.1 mm and 3.2 mm for phantoms and patients respectively.</p> <p>External objects such as the treatment table and ECG leads are often in CT images, affecting the above mentioned 2D/3D registration. To address this, an algorithm for automatic removal of external objects from CT images was developed. This was applied to automatic contouring and removal of the fiducial markers in CT images used for external beam radiation therapy treatment planning for breast cancer. The algorithm was further modified to compute the girth of patients as part of a diagnostic radiology clinical trial.</p>en_US
dc.description.degreeDoctor of Philosophy (PhD)en_US
dc.identifier.otheropendissertations/8127en_US
dc.identifier.other9230en_US
dc.identifier.other4568655en_US
dc.identifier.urihttp://hdl.handle.net/11375/13308
dc.subject2D/3D registrationen_US
dc.subjectlung brachytherapyen_US
dc.subjectcomputed tomographyen_US
dc.subjectPhysicsen_US
dc.subjectPhysicsen_US
dc.title2D/3D Registration Algorithm for Lung Brachytherapyen_US
dc.typethesisen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
fulltext.pdf
Size:
2.81 MB
Format:
Adobe Portable Document Format