Welcome to the upgraded MacSphere! We're putting the finishing touches on it; if you notice anything amiss, email macsphere@mcmaster.ca

Study of the Seismic Response of Unanchored Equipment and Contents in Fixed-Base and Base-Isolated Buildings

dc.contributor.advisorKonstantinidis, Dimitrios
dc.contributor.authorNikfar, Farzad
dc.contributor.departmentCivil Engineeringen_US
dc.date.accessioned2016-04-22T18:21:52Z
dc.date.available2016-04-22T18:21:52Z
dc.date.issued2016
dc.description.abstractImmediate occupancy and functionality of critical facilities including hospitals, emergency operations centers, communications centers, and police and fire stations is of utmost importance immediately after a damaging earthquake, as they must continue to provide fundamental health, emergency, and security services in the aftermath of an extreme event. Although recent earthquakes have proven the acceptable performance of the structural system in such buildings, when designed according to recent seismic design codes, in many cases damage to the nonstructural components and systems was the main cause of disruption in their functionality. Seismic isolation is proven to be an effective technique to protect building structures from damaging earthquakes. It has been the method of choice for critical facilities, including hospitals in Japan and the United States in recent years. Seismic isolation appears to be an ideal solution for protecting the nonstructural components as well. While this claim was made three decades ago, the supporting research for freestanding (unanchored) equipment and contents (EC) is fairly new. With the focus on freestanding EC, this study investigates the seismic performance of sliding and wheel/caster-supported EC in fixed-base and base-isolated buildings. The study adopts a comparative approach to provide a better understanding of the advantages and disadvantages of using each structural system. The seismic response of sliding EC is investigated analytically in the first part of the thesis, while the response of EC supported on wheels/casters is examined through shake table experiments on two pieces of hospital equipment. The study finds base isolation to be generally effective in reducing seismic demands on freestanding EC, but it also exposes certain situations where isolation in fact increases demands on EC. Increasing the frictional resistance for sliding EC or locking the wheel/casters in the case of wheel/caster-supported EC is highly recommended for EC in base-isolated buildings to prevent excessive displacement demands. Furthermore, the study suggests several design probability functions that can be used by practicing engineers to estimate the peak seismic demands on sliding and wheel/caster-supported EC in fixed-base and base-isolated buildings.en_US
dc.description.degreeDoctor of Philosophy (PhD)en_US
dc.description.degreetypeDissertationen_US
dc.identifier.urihttp://hdl.handle.net/11375/19145
dc.language.isoenen_US
dc.subjectNonstructural Components, Base-Isolation, Shake Table Test, Medical Equipment, Hospital, Unanchored Contents, Sliding, Stick-Slip, Wheels and Casters, Fragility Curve, Vision-Based Measurement, Non-contact Measurementen_US
dc.titleStudy of the Seismic Response of Unanchored Equipment and Contents in Fixed-Base and Base-Isolated Buildingsen_US
dc.typeThesisen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
nikfar_farzad_201604_phd.pdf
Size:
15.19 MB
Format:
Adobe Portable Document Format
Description:
PhD Dissertation

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.68 KB
Format:
Item-specific license agreed upon to submission
Description: