Solid Electrolytes and Deoxidation
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
<P> A study has been made of the transformation of deoxidation products in the Fe-V-0 system in the temperature range 1545 -1640°C, using galvanic cells with solid electrolytes. The cells used were in the form of Zr02 (caO) immersion probes and Th02(Y2o2) crucible assemblies. The fields of study of Fev2o4(spinel) and v2o3 were established with respect to oxygen activity and temperature. </p>