Abstract
Rheumatoid arthritis is characterized by severe inflammation of the synovial
tissue in the joint, which causes pain and degradation of the bone. The novel
treatment boron neutron capture synovectomy (BNCS) utilizes the 10B(n,a)7Li
nuclear reaction to ablate the synovial tissue as an attempt to control these effects.
The typical procedure involves intra-articular injection of a boronated compound
followed by irradiation of the joint with a thermalized neutron beam. An
anthropomorphic knee phantom has been designed and manufactured in a manner to
display similar moderating and reactive properties to human soft tissue and bone. The
intended use of such a phantom is the determination of RBE values of boron compounds on several human cell types. Beam line characterization has been
performed on the 3 MV KN single-ended accelerator at McMaster University using
MCNP5. Testing was accomplished for neutron spectra produced by 2.00, 2.15, and
2.25 MeV protons on a thick lithium target. The maximum thermal flux through the
interior cavity of the phantom was attained for moderator thicknesses of 3.25, 3.25,
and 3.5 cm of high-density polyethylene (HDPE) at 2.00, 2.15, and 2.25 MeV,
respectively, via MCNP5 for a phantom position 45° relative to the incident proton
beam. Experimentally determined thermal flux maxima occurred using 1.75, 1.75 and
2.0 cm of HDPE for the corresponding energies. Causes for discrepancies were cited
as phantom material inconsistencies, as well as possible errors in the analytical
compilation of the MCNP5 source cards for the 7Li(p,n)7Be reaction. Experimentally,
selecting a proton energy of 2.25 MeV showed little advantageous characteristics
over 2.15 MeV. It is concluded that a Monte Carlo based code with charged particle
transport capabilities may be desirable for further neutron dosimetry and standardized
materials should be used whenever possible for manufacturing a “neutron phantom”.