Welcome to the upgraded MacSphere! We're putting the finishing touches on it; if you notice anything amiss, email macsphere@mcmaster.ca

Investigation of Thermal Buffer Zone Effectiveness in Real Buildings

dc.contributor.advisorHamed, Mohamed
dc.contributor.authorAlmansour, Abdulrahman
dc.contributor.departmentMechanical Engineeringen_US
dc.date.accessioned2019-04-03T19:30:28Z
dc.date.available2019-04-03T19:30:28Z
dc.date.issued2018
dc.description.abstractGlobal warming is caused by Greenhouse Gas (GHG) emissions produced from the use of fossil fuel-based energy sources. Buildings consume about 30%-35% of the global energy use, which makes buildings a major contributor to the global warming problem. A long-term plan has been established at the Thermal Processing Laboratory (TPL) at McMaster University to investigate the use of various renewable energy-based technologies to achieve Net-Zero Energy Buildings (NZEB) in Canada. This paper presents results of an investigation of the effectiveness of using a thermal buffer zone (TBZ) in real buildings. A TBZ is a closed passage built around the building that allows air to passively re-distribute heat energy from solar radiation received on the south side throughout the building. A TBZ offers an effective solution of the overheating problem usually experienced on the south side of the building and, at the same time, it helps in reducing the heating load of the north side of the building. An experimental setup employing TBZ in a model of a typical building floor has been built. An analytical model of the TBZ has been developed. The experimental data has been used to validate the developed analytical model, which then was used to simulate the performance of a TBZ implemented in a real building floor. Results showed that the effectiveness of TBZ could reach 117% in the winter (cold climate countries). Moreover, the study considered the effect of integrating the TBZ with a fan. Results showed that the use of the fan is beneficial for a certain gap width, beyond which the use of the fan is not recommended. In conclusion, results of this study confirm that the TBZ can offer an effective means of replacing parry of building consumption of fossil fuel-based energy using solar energy.en_US
dc.description.degreeMaster of Applied Science (MASc)en_US
dc.description.degreetypeThesisen_US
dc.identifier.urihttp://hdl.handle.net/11375/24216
dc.language.isoenen_US
dc.subjectPassive air heaten_US
dc.subjectBuffer zoneen_US
dc.titleInvestigation of Thermal Buffer Zone Effectiveness in Real Buildingsen_US
dc.typeThesisen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Almansour_Abdulrahman_M_201810_MASc.pdf
Size:
1.87 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.68 KB
Format:
Item-specific license agreed upon to submission
Description: