Fluid-Structure Interaction in an Isolated Nuclear Power Plant Comparing Linear and Nonlinear Fluid Models

dc.contributor.advisorTait, Michael
dc.contributor.advisorBecker, Tracy
dc.contributor.authorHoekstra, Joshua
dc.contributor.departmentCivil Engineeringen_US
dc.date.accessioned2020-05-04T18:05:25Z
dc.date.available2020-05-04T18:05:25Z
dc.date.issued2020
dc.description.abstractThe long-term operational safety of nuclear power plants is of utmost importance. Seismic isolation has been shown to be effective in reducing the demands on structures in many applications, including nuclear power plants (NPP). Many designs for Generation III+ NPP include a large passive cooling tank as a measure of safety that can be used during power failure. In a large seismic event, the fluid in the tank may be excited, and while the phenomenon of fluid-structure interaction (FSI) has also been studied in the context of base isolated liquid storage tanks, the effect on seismically isolated NPP has not yet been explored. This thesis presents a two-part study on a base isolated NPP with friction pendulum bearings. The first part of the study compares the usage of a linear fluid model to a nonlinear fluid model in determining tank and structural demand parameters. The linear fluid model was found to represent the nonlinear fluid model well for preliminary analysis apart from peak sloshing height, which it consistently underestimated. The second part of the study uses a linear fluid model, an empty tank model and a rigid fluid model to investigate the influence of FSI on the structural response of an isolated NPP compared to a fixed base NPP. In general, the response of a fixed base NPP considering FSI using a linear fluid model can typically be bound by the results assuming an empty tank and assuming a full tank with rigid fluid mass. However, this does not hold for the base isolated NPP, as the peak isolation displacement for an NPP with a linear fluid model at design depth is greater than the peak isolation displacement than the same NPP with an empty tank and with a rigid fluid model.en_US
dc.description.degreeMaster of Applied Science (MASc)en_US
dc.description.degreetypeThesisen_US
dc.identifier.urihttp://hdl.handle.net/11375/25419
dc.language.isoenen_US
dc.subjectFluid-Structure Interactionen_US
dc.subjectNuclear Power Planten_US
dc.subjectBase Isolationen_US
dc.titleFluid-Structure Interaction in an Isolated Nuclear Power Plant Comparing Linear and Nonlinear Fluid Modelsen_US
dc.typeThesisen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Hoekstra_Joshua_A_finalsubmission2020April_MASc.pdf
Size:
1.34 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.68 KB
Format:
Item-specific license agreed upon to submission
Description: