Welcome to the upgraded MacSphere! We're putting the finishing touches on it; if you notice anything amiss, email macsphere@mcmaster.ca

Design and Characterization of a Miniaturized Fluorescence Analysis System for Measurement of Cell-Free DNA

dc.contributor.advisorSelvaganapathy, Ravi
dc.contributor.authorBondi, Parker
dc.contributor.departmentBiomedical Engineeringen_US
dc.date.accessioned2019-03-12T18:54:41Z
dc.date.available2019-03-12T18:54:41Z
dc.date.issued2018-11-30
dc.description.abstractSepsis is a dysregulated systemic response to infection and is one of the leading causes of in-hospital mortality in Canada. Accurate distinction between survivors and non-survivors of sepsis has recently been demonstrated through quantification of cell-free DNA (cfDNA) concentration in blood. In an analysis of 80 septic patients, non-survivors of sepsis had significantly higher cfDNA concentration levels than that of survivors or healthy patients. Real time separation of cfDNA from contaminants in blood has also been done using a cross channel microfluidic device. Current methods for DNA quantification utilize time consuming and complicated laboratory equipment and therefore are not suitable for bedside real-time testing. Thus a handheld cfDNA fluorescence device coined the Sepsis Check was designed that can perform DNA characterization in a reservoir device and DNA detection in a microfluidic cross channel device. The goal is to use this system along with the cross channel devices to set apart survivors or healthy donors from non-survivors in patients with sepsis. The design consists of a 470๐‘›๐‘š light emitting diode (LED) with 170๐‘š๐‘Š of optical power (LED470L โ€“ ThorLabs), an aspherical uncoated lens with a focal length of 15๐‘š๐‘š (LA1540-ML โ€“ ThorLabs), a 488๐‘›๐‘š bandpass filter with a 3๐‘›๐‘š full width at half maximum (FWHM) (FL05488-3 โ€“ ThorLabs), an aspherical uncoated lens with a focal length of 25๐‘š๐‘š (LA1560-ML โ€“ ThorLabs), an aspherical uncoated lens with a focal length of 35๐‘š๐‘š (LA1027-ML โ€“ ThorLabs), a 525๐‘›๐‘š longpass filter with an optical density >4.0 (F84744 โ€“ Edmund Optics), and a Raspberry Pi Camera V2 (Raspberry Pi Foundation). The Sepsis Check is made to excite the dsDNA specific PicoGreen fluorophore which has a peak absorbance at 502๐‘›๐‘š and a peak emission at 523๐‘›๐‘š. In summary, the Sepsis Check in this thesis is capable of calibrating dsDNA concentration from 1๐œ‡๐‘”/๐‘š๐ฟ to 10๐œ‡๐‘”/๐‘š๐ฟ and detect DNA accumulation of 5๐œ‡๐‘”/๐‘š๐ฟ and 10๐œ‡๐‘”/๐‘š๐ฟ in the cross channel device. This tool can be a valuable addition to the ICU to rapidly assess the severity of sepsis for informed decision making.en_US
dc.description.degreeMaster of Applied Science (MASc)en_US
dc.description.degreetypeThesisen_US
dc.identifier.urihttp://hdl.handle.net/11375/23998
dc.language.isoenen_US
dc.subjectMiniaturized Fluorescence Systemen_US
dc.subjectCell-Free-DNAen_US
dc.subjectSepsis Quantificationen_US
dc.titleDesign and Characterization of a Miniaturized Fluorescence Analysis System for Measurement of Cell-Free DNAen_US
dc.typeThesisen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Bondi_Parker_FinalSubmission201812_MAScBME.pdf
Size:
4.99 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.68 KB
Format:
Item-specific license agreed upon to submission
Description: