Integrated Control of Multiple Cooling Units

dc.contributor.advisorDown, Douglas
dc.contributor.advisorBadawy, Ghada
dc.contributor.authorMozaffari, Shirin
dc.contributor.departmentComputing and Softwareen_US
dc.date.accessioned2019-10-07T14:05:44Z
dc.date.available2019-10-07T14:05:44Z
dc.date.issued2019
dc.description.abstractData centres are an integral part of today's technology. With the growing demand for data centers to meet computational needs, there is pressure to decrease data center-related costs. By reducing the amount of power needed to cool servers, the overall power consumption can be decreased. Efficient cooling of data centres involves meeting temperature constraints while minimizing power consumption. By exploring the opportunities that may be available through controlling multiple cooling units, we can avoid issues such as overcooling (some parts of the data center being cooled more than necessary) or warm air recirculation (return of exhausted hot air to inlets of servers). Currently, in data centres with more than one cooling unit, each of the cooling units is controlled independently. This mode of operation results in each cooling unit needing to be set for the worst case, which results in over cooling and is not energy efficient. Coordinating cooling units has the potential to decrease the power consumption of a data centre by eliminating this over cooling. Furthermore, coordinating with workload management may help mitigate cooling unit power consumption. This research is concerned with exploring what is feasible within the options discussed above. It contains two main parts. In the first part, we present an algorithm to minimize power consumption of cooling units while keeping all the server cores below a temperature threshold. In the second part of this thesis, we derived a data-driven model for server outlet temperature.en_US
dc.description.degreeMaster of Science (MSc)en_US
dc.description.degreetypeThesisen_US
dc.identifier.urihttp://hdl.handle.net/11375/24988
dc.language.isoenen_US
dc.subjectData Centreen_US
dc.subjectCoolingen_US
dc.subjectZoneen_US
dc.subjectPower Consumptionen_US
dc.titleIntegrated Control of Multiple Cooling Unitsen_US
dc.typeThesisen_US

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
Mozaffari_Shirin_2019August_master.pdf
Size:
3.39 MB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
Final Submission sheet.pdf
Size:
364.94 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.68 KB
Format:
Item-specific license agreed upon to submission
Description: