Modeling Film Boiling and Quenching on the Outer Surface of a Calandria Tube Following a Critical Break Loca in a CANDU Reactor

dc.contributor.advisorLuxat, John C.
dc.contributor.authorJiang, Jian Tao
dc.contributor.departmentEngineering Physicsen_US
dc.date.accessioned2017-07-25T22:06:56Z
dc.date.available2017-07-25T22:06:56Z
dc.date.issued2008-04
dc.description.abstract<p> In a postulated critical break LOCA in a CANDU reactor it is possible that heatup of a pressure tube (PT) causes ballooning contact with the calandria tube (CT). Stored heat in the PT is transferred out, yielding a high PT-CT heat flux, which can cause dry out of the CT and establishment of pool film boiling on the outer surface of the tube. The safety concern associated with this condition is that if the temperature of the CT experiencing film boiling gets sufficiently high then failure of the fuel channel may occur. However, quench heat transfer can limit the extent and duration of film boiling as has been experimentally observed. Current estimates of quench temperatures during pool film boiling are based primarily on experimental correlations. In this dissertation a novel mechanistic model of pool film boiling on the outside of a horizontal tube with diameter relevant to CT (approximately 130 mm) has been developed. The model is based in part upon characterizing the vapor film thickness for steady state film boiling under buoyancy driven natural convection flows around a tube located horizontally in a large liquid pool. Variations in steady state vapor film thickness as a function of the incident heat flux, the temperature of the CT outer wall, and the subcooling of the bulk liquid are analyzed. The calculated effective film boiling heat transfer coefficient is compared to available experimental data. Finally a transient equation is developed which quantifies the instability of the vapor film and a possible occurrence of rapid quench when a step change in governing parameters occurs, such as liquid subcooling. This mechanistic model can be employed in safety analysis to demarcate the conditions under which fuel channel failure will not occur in a postulated critical break LOCA.</p>en_US
dc.description.degreeMaster of Applied Science (MASc)en_US
dc.description.degreetypeThesisen_US
dc.identifier.urihttp://hdl.handle.net/11375/21772
dc.language.isoen_USen_US
dc.subjectmoedling film, boiling, quenching, calandria tube, critical break loca, CANDU reactor, incident heat fluxen_US
dc.titleModeling Film Boiling and Quenching on the Outer Surface of a Calandria Tube Following a Critical Break Loca in a CANDU Reactoren_US
dc.typeThesisen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Jiang_Jian_T._2008Apr_Masters..pdf
Size:
12.67 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.68 KB
Format:
Item-specific license agreed upon to submission
Description: