Title: Cold-Cracking Control in Low-Alloy Steel Welds
Authors: Pavaskar, Vivek
Advisor: Kirkaldy, J.S.
Department: Metallurgy and Materials Science
Keywords: Materials Science and Engineering;Metallurgy;Materials Science and Engineering
Publication Date: Sep-1979
Abstract: <p>BAZ microstructure stress and hydrogen level are the fundamental factors influencing the cold cracking susceptibility of the HAZ. Implant testing at various hydrogen levels over a range of steel compositions and heat inputs shows how the microstructure and hydrogen level influence the critical stress necessary for cold-cracking.</p> <p>Based on implant test data, a correlation formula predicting the critical stress necessary for cold cracking for given HAZ hardness martensite in the HAZ and hydrogen level, is proposed. Employing this correlation, together with prediction of martensite in the HAZ and HAZ hardness, based on heat transfer caculations, martensite-composition-cooling rate relations and hardness-composition-cooling rate relations, an algorithms which can predict the critical stress necessary for cracking for given implant composition, cooling rate and hydrogen level, is constructed.</p> <p>This method of predicting the critical stress necessary for cold cracking is an improvement over the existing regression formulas for estimating cold-cracking susceptibility.</p> <p>This formula has been successfully adapted to predict cold-cracking susceptibility data as obtained through other tests such as rigid restraint, and to recommend prehear levels necessary to avoid cold-cracking. Development and use of implant testing machine with an automatic welding and loading facility is also reported.</p>
URI: http://hdl.handle.net/11375/7477
Identifier: opendissertations/2753
3823
1409733
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
6.26 MBAdobe PDFView/Open
Show full item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue