Title: Energy Margin Calculation by the Relevant Fault-on Trajectory Method
Authors: Tang, Chi-keung
Advisor: Alden, R.T.H.
Findlay, Raymond D.
El-Kady, Mohamed A.
Department: Electrical Engineering
Keywords: Electrical and Electronics;Electrical and Electronics
Publication Date: 1995
Abstract: <p>The value of the time domain simulation technique for power system transient stability analysis can be greatly enhanced if it can indicate the degree of stability by producing a stability index. Often referred to as Energy Margin, the stability index offers additional insight into the transient stability problem being studied, and has the capability of speeding up transient stability limit derivations. Moreover, energy margins also have potential applications in dynamic contingency ranking and screening.</p> <p>This thesis presents a new method, called the Relevant Fault-on Trajectory (RFT) method, for incorporating energy margin calculations into time domain simulations. The proposed method is based on the determination of the additional energy absorbing capability of the critical generator group, at the instant when the transient kinetic energy injected into this group by the disturbance is fully absorbed. The additional energy absorbing capability is obtained through the simulation of a relevant fault-on trajectory. The RFT method computes energy margins efficiently and reliably for systems exhibiting either plant mode or area mode stability problems.</p> <p>The practicality of the proposed method has been successfully demonstrated on a 27-generator, an 89-generator, and a 144-generator system. The RFT method has the capability of speeding up transient stability limit derivation by reducing the number of stability runs.</p>
URI: http://hdl.handle.net/11375/7004
Identifier: opendissertations/2304
3250
1370468
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
3.02 MBAdobe PDFView/Open
Show full item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue