Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Departments and Schools
  3. Faculty of Engineering
  4. Department of Mechanical Engineering
  5. Mechanical Engineering Publications
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/31168
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAmmar A-
dc.contributor.authorAlsadi N-
dc.contributor.authorAdachi JD-
dc.contributor.authorGadsden SA-
dc.contributor.authorQuenneville CE-
dc.date.accessioned2025-02-27T16:54:27Z-
dc.date.available2025-02-27T16:54:27Z-
dc.date.issued2024-01-19-
dc.identifier.issn2168-1163-
dc.identifier.issn2168-1171-
dc.identifier.urihttp://hdl.handle.net/11375/31168-
dc.description.abstractHip fractures contribute significantly to mortality in older adults. New methods to identify those at risk use dual-energy X-ray absorptiometry (DXA) images and advanced image processing. However, DXA images have an overlapping femur and pelvis and may contain boundary lines, making automation challenging. Herein, a 5-layer U-net convolutional neural network (CNN) was developed to segment the femur from hip DXA images. Images were used from the Canadian Longitudinal Study on Aging (CLSA, N=104) and Canadian Multicentre Osteoporosis Study (CaMos, N=105) databases for training, with manual contour drawing defining the ‘true output’ of each image. An algorithm was then developed to mask each hip image, and trained to predict subsequent masks. The CNN was tested with 44 additional CLSA images and 42 CaMos images. This proposed approach had an accuracy and intersection over union (IoU) of 97% and 0.57, and 93% and 0.51, for CaMos and CLSA scans, respectively. Furthermore, a series of augmentation techniques was applied to increase the data size, with accuracies of 96% and 94%, and IoU of 0.53 and 0.50. Overall, our strategy automatically determined the contour of the proximal femur using various clinical DXA images, a key step to automate fracture risk assessment in clinical practice.-
dc.publisherTaylor & Francis-
dc.subject46 Information and Computing Sciences-
dc.subjectBiomedical Imaging-
dc.subjectBioengineering-
dc.subjectMachine Learning and Artificial Intelligence-
dc.subjectAging-
dc.subjectOsteoporosis-
dc.subjectPrevention-
dc.subjectMusculoskeletal-
dc.titleA CNN-based strategy to automate contour detection of the hip and proximal femur using DXA hip images from longitudinal databases (CLSA and CaMos)-
dc.typeArticle-
dc.date.updated2025-02-27T16:54:25Z-
dc.contributor.departmentMechanical Engineering-
dc.identifier.doihttps://doi.org/10.1080/21681163.2023.2296626-
Appears in Collections:Mechanical Engineering Publications

Files in This Item:
File Description SizeFormat 
099-CNN-basedstrategytoautomatecontourdetection.pdf
Open Access
Published version5.36 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue