Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/29295
Title: A Label-Free Electrochemical Biosensing Approach for Modern Diagnostics Using Screen-Printed Electrodes
Authors: Grewal, Rehmat
Advisor: Rajabzadeh, Amin
Srinivasan, Seshasai
Department: Biomedical Engineering
Keywords: Electrochemical;Label-free;Modern Diagnostics;Differential Pulse Voltammetry;Glycated Hemoglobin (HbA1c);C-Reactive Protein (CRP);Δ9-tetrahydrocannabinol (THC);Square Wave Voltammetry;Coronary Heart Disease (CHD);Stability
Publication Date: 2024
Abstract: Electrochemical biosensors are renowned for their ability to detect a wide range of analytes in biological fluids for clinical diagnosis. The implementation of biomarkers in electrochemical biosensors for clinical diagnosis is essential for the specific and accurate diagnosis of the disease with high sensitivity and selectivity. Therefore, this thesis evaluates the challenges pertaining to the stability, reproducibility, and obtaining a low limit of detection for the internal/external biomarkers associated with two distinct electrochemical biosensors. The first study tackles the challenge of detecting low analyte concentrations in a label-free biosensor. It introduces an innovative label-free electrochemical biosensing method for the detection of glycosylated hemoglobin (HbA1c) and C-reactive protein (CRP) to predict Coronary Heart Disease (CHD) progression using tailored redox probes, proposing a dual biomarker biosensing platform for future research. Calibration curves reveal an LOD of 5 mg/mL in PBS (8) FeCN (II) and 6 mg/mL in SB for a linear range of 0 – 30 mg/mL of HbA1c. Similarly, an LOD of 0.007 mg/mL and 0.008 mg/mL in PBS (7.4) PcA-NO2 and SB, respectively, is reported for a linear range of 0 – 0.05 mg/mL of CRP. The second study focuses on stabilizing a biomolecule-free sensor for the ultra-low detection of Δ9-tetrahydrocannabinol (THC) in roadside testing. Pre-depositing THC, an external biomarker for drug-impaired driving, onto the biosensor's working electrode enhances its interaction with analytes. However, THC's oxidative nature compromises sensor stability during manufacturing. Consequently, optimal electrode storage conditions were explored, indicating frozen storage as ideal for up to six months, effectively preventing THC oxidation at -18°C, while degradation occurs at 4°C. Modified electrodes stored under optimal conditions exhibit improved calibration curves when exposed to various THC samples.
URI: http://hdl.handle.net/11375/29295
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File Description SizeFormat 
Grewal_Rehmat_Nov2023_MASc.pdf
Access is allowed from: 2024-11-16
MASc Graduate Thesis6.49 MBAdobe PDFView/Open
Show full item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue