Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/27881
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorByun, Soohyun-
dc.contributor.authorRen, Tianyi-
dc.date.accessioned2022-09-28T01:41:06Z-
dc.date.available2022-09-28T01:41:06Z-
dc.date.issued2022-
dc.identifier.urihttp://hdl.handle.net/11375/27881-
dc.description.abstractOne of the main challenges during the ultra-high count rate gamma-ray spectrometry is the large dead time. Using a LaBr3(Ce) detector (TRT 0.3 µs, TFT 0.5 µs), with an input count rate of 4.8×10E5 cps, the dead time could be as high as 87%. Such high dead time could significantly reduce the quality of the data collected as a considerable number of counts would be lost. Thus, this project aimed to reduce the dead time by modifying the detector system. Based on the setup used by previous research, the new system has its preamp, which is normally used for signal processing, removed. Experiments were made with calibration sources to optimize the new system. The calibration sources (Cs-137 and Co-60), Cs-137 resin sources, and Shephard Cs-137 sources were used to create different count rates, with the highest being 1.22×10E6 cps, for measurements. Side-by-side measurements were performed with the setup with preamp and the one without preamp at various count rates. The analysis, which focused on the dead time and resolution, shows the setup without preamp would have much lower dead time, especially during ultra-high count rate measurements. The method was proved to be successful, for, at 4.8×10E5 cps, the dead time decreased from 87% to 54%.en_US
dc.language.isoenen_US
dc.subjectLaBr3 detectoren_US
dc.subjectGamma-ray Spectrometryen_US
dc.titleSolving the Extremely High Dead Time During Ultra-High-rate Gamma-ray Spectrometry Using a LaBr3(Ce) Detectoren_US
dc.typeThesisen_US
dc.contributor.departmentRadiation Sciences (Medical Physics/Radiation Biology)en_US
dc.description.degreetypeThesisen_US
dc.description.degreeMaster of Science (MSc)en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File Description SizeFormat 
Ren_Tianyi_202209_M.Sc.pdf
Open Access
3.4 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue