Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/27039
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorDoyle, Thomas-
dc.contributor.authorSimons, Ama-
dc.date.accessioned2021-10-12T15:10:27Z-
dc.date.available2021-10-12T15:10:27Z-
dc.date.issued2021-
dc.identifier.urihttp://hdl.handle.net/11375/27039-
dc.description.abstractTrust is explored in this thesis through the analysis of the robustness of wearable device based artificial intelligence based models to changes in data acquisition. Specifically changes in wearable device hardware and different recording sessions are explored. Three human activity recognition models are used as a vehicle to explore this: Model A which is trained using accelerometer signals recorded by a wearable sensor referred to as Astroskin, Model H which is trained using accelerometer signals from a wearable sensor referred to as the BioHarness and Model A Type 1 which was trained on Astroskin accelerometer signals that was recorded on the first session of the experimental protocol. On a test set recorded by Astroskin Model A had a 99.07% accuracy. However on a test set recorded by the BioHarness Model A had a 65.74% accuracy. On a test set recorded by BioHarness Model H had a 95.37% accuracy. However on a test set recorded by Astroskin Model H had a 29.63% accuracy. Model A Type 1 an average accuracy of 99.57% on data recorded by the same wearable sensor and same session. An average accuracy of 50.95% was obtained on a test set that was recorded by the same wearable sensor but by a different session. An average accuracy of 41.31% was obtained on data that was recorded by a different wearable sensor and same session. An average accuracy of 19.28% was obtained on data that was recorded by a different wearable sensor and different session. An out of domain discriminator for Model A Type 1 was also implemented. The out of domain discriminator was able to differentiate between the data that trained Model A Type 1 and other types (data recorded by a different wearable devices/different sessions) with an accuracy of 97.60%.en_US
dc.language.isoenen_US
dc.subjecttrust, human activity recognition, artificial intelligence, wearable devicesen_US
dc.titleTrust in Human Activity Recognition Deep Learning Modelsen_US
dc.typeThesisen_US
dc.contributor.departmentBiomedical Engineeringen_US
dc.description.degreetypeThesisen_US
dc.description.degreeMaster of Applied Science (MASc)en_US
dc.description.layabstractThe trustworthiness of artificial intelligence must be explored before society can fully reap its benefits. The element of trust that is explored in this thesis is the robustness of wearable device based artificial intelligence models to changes in data acquisition. The specific changes that are explored are changes in the wearable device used to record the input data as well as input data from different recording sessions. Using human activity recognition models as a vehicle, the results show that performance degradation occurs when the wearable device is changed and when data comes from a different recording session. An out of domain discriminator is developed to alert users when a potential performance degradation can occur.en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File Description SizeFormat 
Ama_Thesis (8).pdf
Open Access
6.84 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue