Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Departments and Schools
  3. Faculty Publications
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/25184
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWiebe, Lydell-
dc.contributor.authorChristopoulos, Constantin-
dc.date.accessioned2020-01-15T18:08:31Z-
dc.date.available2020-01-15T18:08:31Z-
dc.date.issued2015-
dc.identifier10.1002/eqe.2549-
dc.identifier.issn10.1002/eqe.2549-
dc.identifier.urihttp://hdl.handle.net/11375/25184-
dc.description.abstractThis paper examines higher mode effects in systems where the ductile mechanism for seismic design is the base moment‐rotation response. The modal properties of flexural and shear beams with uniform mass and elasticity and with a variable amount of base rotational restraint are derived. As the base fixity is released, the first mode becomes the rigid body rotation of the beam about the base, but the higher modes change much less, particularly for the shear beam model. Most response quantities that are of interest in the seismic design of typical mid‐rise buildings are controlled by the first two lateral modes, except at locations along the height where the second mode contributes little. However, the third and higher lateral modes are more significant for high‐rise buildings. Based on the theory of uniform cantilever shear beams, expressions are developed to avoid the need for a modal analysis to estimate the overturning moment, storey shear, and floor acceleration envelopes. Considering the measured response from the shake table testing of a large‐scale eight‐storey controlled rocking steel braced frame, the proposed expressions are shown to be of similar or better accuracy to a modified modal superposition technique, which combines the higher mode response from an elastic modal analysis with the response associated with achieving the maximum base overturning moment according to an inverted triangular load distribution. Because the proposed method uses only parameters that are available at the initial design stage, avoiding the analysis of a structural model, it is likely to be especially useful for preliminary design.en_US
dc.language.isoenen_US
dc.publisherWileyen_US
dc.titleA cantilever beam analogy for quantifying higher mode effects in multistorey buildingsen_US
dc.typePostprinten_US
dc.contributor.departmentCivil Engineeringen_US
Appears in Collections:Faculty Publications

Files in This Item:
File Description SizeFormat 
Wiebe Christopoulos AM with Cover.pdf
Open Access
833.31 kBAdobe PDFView/Open
Corrigenda.pdf
Open Access
189.24 kBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue