dc.identifier.urihttp://hdl.handle.net/11375/23240-
dc.description.abstractHelical heating coils are widely used in most conventional electric stoves for many years, these heating coils can reach 600-700°C, which is higher than the ignition point of oil and grease (about 400°C), leading to many fires. Pioneering Technology Inc. has developed a Safe-T Element plate to address such problem. The Safe-T Element plate is manufactured from Gray Cast Iron. However, these plates deform during its use. This study was carried out to investigate the current Safe-T Element design, both experimentally and numerically, in order to determine the root causes behind the deformation problem of the plate, and to suggest changes to the existing design in order to limit its distortion to acceptable targets. A chemical analysis was carried out to establish the type of material of the Safe-T Element plate. Chemical analysis showed that the material of the plate is cast iron. The microstructure of the plate was tested in order to examine its type and homogeneity. Tensile testing was carried to establish the grade of the material, and to calculate the value of its young's modulus and yield strength. Tensile testing indicated that the material of the Safe-T Element plate is close to Gray Cast Iron Class 40. Differential scanning calorimetry testing was carried out to investigate thermal stability of the plate material. This test indicated that material is thermally stable. Thermal cycling testing indicated that the root cause of the deformation problem is elastic thermal buckling. Temperature uniformity tests were carried out. More than 100°C temperature variation in the radial direction was observed. To address the distortion of the plate, an optimum geometry has been suggested based on the findings of the numerical investigation by removing the outer ring from the original design of the plate.en_US
dc.language.isoenen_US
dc.subjectnumerical studyen_US
dc.subjectexperimental studyen_US
dc.subjectdeformationen_US
dc.subjectgray cast ironen_US
dc.subjectcast ironen_US
dc.subjectplatesen_US
dc.titleNumerical and Experimental Study of the Deformation of Gray Cast Iron Platesen_US
dc.typeThesisen_US
dc.contributor.departmentMechanical Engineeringen_US
dc.description.degreetypeThesisen_US
dc.description.degreeMaster of Applied Science (MASc)en_US
Appears in Collections:Digitized Open Access Dissertations and Theses

Files in This Item:
File Description SizeFormat 
iqbal_khurram_2009Feb_masters.pdf
Open Access
21.45 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue