Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Departments and Schools
  3. Faculty of Engineering
  4. Department of Electrical and Computer Engineering
  5. EE 4BI6 Electrical Engineering Biomedical Capstones
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/14424
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDe, Armas Winstonen_US
dc.date.accessioned2014-06-18T18:13:15Z-
dc.date.available2014-06-18T18:13:15Z-
dc.date.created2011-02-18en_US
dc.date.issued2010-04-22en_US
dc.identifier.otheree4bi6/24en_US
dc.identifier.other1023en_US
dc.identifier.other1796404en_US
dc.identifier.urihttp://hdl.handle.net/11375/14424-
dc.description.abstract<p>For patients at risk of developing cardiovascular complications, it is important to monitor their heart signal to ensure proper functioning of their heart and a natural, healthy cardiac cycle. Preferably, this monitoring should be done on a continuous and long-term basis. Both of these objectives can be achieved using the electrocardiogram. While the traditional 12-lead ECG is currently used in hospital and clinical settings, the number of wires and the need for an electrolytic paste makes the setup very inconvenient, invasive and unsuitable for long-term use. The goal is to develop a clinical diagnostic system to take physiological signals from the patient and transmit it to a base station. This could permit the patient to be ambulatory and lead a relatively active life without being confined to a specific region. The project deals specifically with the design of a dry, portable ECG device for this system. The exclusion of wet electrodes without direct patient contact is achieved using the insulated dry electrode. The fundamental concept involved is the principle of capacitive coupling and the use of an impedance transformation circuit at the head stage. An insulating dielectric layer is placed in direct contact with the patient’s skin and a metal electrode goes on top. The electrode carries an AC bioelectric signal through the capacitance of the coupling and this can then be conditioned in the analog domain. An analog ECG signal can be extracted, which can be digitized and logged. The theory behind the device, hardware design and experimental results are presented.</p>en_US
dc.subjectECGen_US
dc.subjectelectrocardiographen_US
dc.subjectcapacitive couplingen_US
dc.subjectdry electrodeen_US
dc.subjectinsulated dry electrodeen_US
dc.subjectnon-contacten_US
dc.subjectlong-termen_US
dc.subjectmonitoringen_US
dc.subjectphysiological signalsen_US
dc.subjectarrhythmiaen_US
dc.subjectBiomedicalen_US
dc.subjectElectrical and Computer Engineeringen_US
dc.subjectBiomedicalen_US
dc.titleDesign of a Non-intrusive 2-lead ECG System Using the Active Insulated Electrodeen_US
dc.typecapstoneen_US
Appears in Collections:EE 4BI6 Electrical Engineering Biomedical Capstones

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
769.96 kBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue