Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/14135
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorEl-Dakhakhni, Waelen_US
dc.contributor.advisorMekky, Waleeden_US
dc.contributor.authorWybenga, Brent M.en_US
dc.date.accessioned2014-06-18T17:06:26Z-
dc.date.available2014-06-18T17:06:26Z-
dc.date.created2014-04-22en_US
dc.date.issued2014en_US
dc.identifier.otheropendissertations/8964en_US
dc.identifier.other10011en_US
dc.identifier.other5508644en_US
dc.identifier.urihttp://hdl.handle.net/11375/14135-
dc.description.abstract<p>The focus of this study is on evaluating the performance of nine, one-third scale, arching, reinforced masonry (RM) walls subjected to blast loads and three, one-third scale arching, RM walls subjected to out-of-plane static airbag loads. These RM walls were supported on four sides to enforce two-way arching allowing the ability to monitor individual response to varying levels of blast loads and standoff distances. The uniformity of the blast pressure and impulse were ensured by a specifically designed test enclosure, diminishing the wrap-around and clearing effects, allowing valuable data to be documented. The damage levels noted, ranged from Superficial to Blowout compared directly to the CSA S850-12 performance limits. The outcome of this experiment demonstrates the beneficial effect of two-way arching on the flexural behaviour of RM walls under impulsive loading. The use of two-way arching RM walls significantly reduces structural damage and increases out-of-plane resistance, which in turn enhances the overall structural integrity and building preservation. Further, when subjected to blast, two-way arching RM walls considerably reduces debris and their dispersal, thus increasing public safety and minimizing hazard levels. When using the experimental test data results to calibrate finite element models (FEM), more analytical data points can be obtained and therefore getting a larger range of scaled distances and trials. The validation of the LS-DYNA model can be used as an alternative to the costly experimental data, as the information collected concluded that the FEM gave damage patterns and failure modes that were comparable with experimental results. The test data collected provides a better understanding of RM wall response to blast loads and to the ongoing Masonry Blast Performance Database (MBPD) project at McMaster University. The generated MBPD will in turn contribute to masonry design clauses in the future editions of the recently introduced Canadian Standards CSA S850-12 “Design and Assessment of Buildings Subjected to Blast Loads”.</p>en_US
dc.subjectarchingen_US
dc.subjectblast loadingen_US
dc.subjectblast scalingen_US
dc.subjectexperimental testingen_US
dc.subjectout-of-planeen_US
dc.subjectreinforced masonryen_US
dc.subjectCivil Engineeringen_US
dc.subjectStructural Engineeringen_US
dc.subjectCivil Engineeringen_US
dc.titleCapacity Quantification of Two-Way Arching Reinforced Masonry Walls under Blast Loadsen_US
dc.typethesisen_US
dc.contributor.departmentCivil Engineeringen_US
dc.description.degreeMaster of Applied Science (MASc)en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
26.14 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue