Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/14022
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorAnand, Christopheren_US
dc.contributor.authorMozafari, Mehrdaden_US
dc.date.accessioned2014-06-18T17:06:03Z-
dc.date.available2014-06-18T17:06:03Z-
dc.date.created2014-03-18en_US
dc.date.issued2008-06en_US
dc.identifier.otheropendissertations/8852en_US
dc.identifier.other9935en_US
dc.identifier.other5352585en_US
dc.identifier.urihttp://hdl.handle.net/11375/14022-
dc.description.abstract<p>Pixel values in MR images are linear combinations of contributions from multiple tissue fractions. The tissue fractions can be recovered using the Moore-Penrose pseudo-inverse if the tissue parameters are known, or can be deduced using machine learning. Acquiring sufficiently many source images may be too time consuming for some applications. In this thesis, we show how tissue fractions can be recovered from partial k-space data, collected in a fraction of the time required for a full set of experiments. The key to reaching significant sample reductions is the use of regularization. As an additional benefit, regularizing the inverse problem for tissue fractions also reduces the sensitivity to measurement noise. Numerical simulations are presented showing the effectiveness of the method, showing three tissue types. Clinically, this corresponds to liver imaging, in which normal liver, fatty liver and blood would need to be included in a model, in order to get an accurate fatty liver ratio, because all three overlap in liver pixels (via partial voluming).</p>en_US
dc.subjectComputing and Softwareen_US
dc.titleModel-Based Tissue Quantification from Simulated Partial k-Space MRI Dataen_US
dc.typethesisen_US
dc.contributor.departmentComputing and Softwareen_US
dc.description.degreeMaster of Science (MSc)en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
37.35 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue