Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/13671
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorFarncombe, Troy H.en_US
dc.contributor.authorSmith, Jamieen_US
dc.date.accessioned2014-06-18T17:04:48Z-
dc.date.available2014-06-18T17:04:48Z-
dc.date.created2013-11-14en_US
dc.date.issued2007-11en_US
dc.identifier.otheropendissertations/8506en_US
dc.identifier.other9584en_US
dc.identifier.other4822925en_US
dc.identifier.urihttp://hdl.handle.net/11375/13671-
dc.description.abstract<p>Objective: The design of a prototype avalanche photodiode gamma camera and an adaptable and expandable acquisition board. To test the performance of the acquisition board a photomultiplier base camera is constructed and utilized in various configurations. The APD-based gamma camera is tested on the same acquisition board to evaluate its performance.</p> <p>Results:Spectra have been collected and analyzed utilizing four various detector/system configurations. i) a PET module, utilizing a PMT coupled to a pixilated BGO crystal with a high energy Na-22 source. ii) a single PMT extracted from a PET module akin to the one mentioned previously and coupled to NaI(T1) with a Co-57 source. iii) the same PMT coupled to a CsI(T1) crystal with a variety of sources, including Tc-99m, Ga-67 and Co37. iv) an APD coupled to a CsI(T1) crystal with a variety of sources including Tc-99m and Co-57. Images have been collected from multiple camera configurations, all by a 2 by 2 array. APD's with CsI(T!), PMT's and NaI(T1) and a PET module with PMT's on BGO</p> <p>Conclusion: These requirements have been met with the current design and the system has been tested in a controlled environment. collecting spectrum while operating a single channel and for some configurations, images were collected operating a multi-channel array. A number of steps can be taken to improve upon this prototype, The detector itself may benefit from a pixilated crystal and current APD technology. The acquisition board should be transferred to a multiple printed circuit board design allowing it to be implemented ill a black-box manner. Additionally. the current USB bridge' limits the transfer rate of data between the DSC and the' PC. as a result. alternatives should be investigated.</p>en_US
dc.subjectOther Medical Sciencesen_US
dc.subjectOther Physicsen_US
dc.subjectOther Medical Sciencesen_US
dc.titleDesign and Construction of an Avalanche Photodioclc-Based Gamma CRmera Prototypeen_US
dc.typethesisen_US
dc.contributor.departmentMedical Physicsen_US
dc.description.degreeMaster of Science (MSc)en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
3.54 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue