Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/13263
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorHoffman, T. W.en_US
dc.contributor.authorAdegbesan, Olutunmbi Kehindeen_US
dc.date.accessioned2014-06-18T17:03:26Z-
dc.date.available2014-06-18T17:03:26Z-
dc.date.created2013-09-12en_US
dc.date.issued1977-10en_US
dc.identifier.otheropendissertations/8081en_US
dc.identifier.other9259en_US
dc.identifier.other4581409en_US
dc.identifier.urihttp://hdl.handle.net/11375/13263-
dc.description.abstract<p>The oxidation of o-xylene was investigated in an integral packed bed reactor using a K<sub>2</sub>SO<sub>4</sub> promoted vanadium pentoxide catalyst on a TiO<sub>2</sub> support.</p> <p>Reaction products consisting of nine chemical components were analyzed by a new temperature-programmed gas chromatographic technique using three different columns to effect separation.</p> <p>A kinetic model based on the REDOX (catalyst reduction and oxidation) mechanism was employed. The statistical method of experimental design for parameter estimation based on M.J. Box's modification [116] of the Draper and Hunter method [47] was used. Statistical analysis based on the eigenvalue-eigenvector method of Box et al. [45] indicated correlation among the responses and this method was used to transform the multiple response data for use in estimating the parameters in the kinetic model.</p> <p>Since parameter estimates in the model were available from Wainwright's previous work [26], the method of Hoffman and Reilly [124] which is based on Bayes' theorem, was used to transfer this prior infonnation on the parameters to the present experimental system.</p> <p>The kinetic data obtained from using the new chromatographic technique developed in this study were found to be consistent. The kinetic model of Wainwright [26] for this reaction system was fitted to the multiple response data obtained from this study. The adequacy of this model in representing the. data was also tested. The use of the statistical teclmiques in experimental programs to develop kinetic models was found to be extremely effective. Some of the difficulties in using them are outlined.</p>en_US
dc.subjectChemical Engineeringen_US
dc.subjectChemical Engineeringen_US
dc.titleOxidation of o-xylene in an integral packed bed reactoren_US
dc.typethesisen_US
dc.contributor.departmentChemical Engineeringen_US
dc.description.degreeMaster of Engineering (ME)en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
6.47 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue