Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/12962
Title: RETROFIT OF STRUCTURAL STEEL COLUMNS USING FRP-CONCRETE COMPOSITE SYSTEMS
Authors: Linde, Joel
Advisor: Tait, M.J.
Razavi, S.N.
Department: Civil Engineering
Keywords: Civil Engineering;Civil Engineering
Publication Date: 2013
Abstract: <p>Fiber reinforced polymer (FRP) - confined concrete-steel composite columns have been recently introduced as a retrofit technique for structural steel columns. This technique involves placing an FRP tube around an in situ steel column and subsequently filling the void between the steel section and the FRP tube with concrete to create a composite column. The composite action occurs due to the concrete encasing the steel section and the FRP confining the concrete. An experimental investigation has been undertaken to evaluate: the effect of adding a steel W section to confined concrete; the effect of using a split tube system as a practical application technique; and the effect of shrinkage reducing admixture in confined concrete. A total of eighteen stub columns, consisting of six different column types were tested to meet these objectives. It was found that the load-displacement response of confined concrete that includes a steel W section is similar to the response of confined concrete plus the elastic-perfectly plastic steel contribution. Experimental findings demonstrate the enhanced performance of the proposed split tube retrofit technique. An analytical model was used to predict the response of the different column types. A method is proposed to incorporate the increased stiffness of the FRP jacket in the split tube system and is shown to be an improvement on the original model. A parametric study was also performed on the revised model.</p>
URI: http://hdl.handle.net/11375/12962
Identifier: opendissertations/7802
8839
4061813
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
4.57 MBAdobe PDFView/Open
Show full item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue