Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/12701
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorKnights, A. P.en_US
dc.contributor.advisorY. Haddara and Dr. L. Soleymanien_US
dc.contributor.authorIBNA, SHAIKH MD ASKERen_US
dc.date.accessioned2014-06-18T17:00:27Z-
dc.date.available2014-06-18T17:00:27Z-
dc.date.created2012-10-25en_US
dc.date.issued2012-04en_US
dc.identifier.otheropendissertations/7565en_US
dc.identifier.other8628en_US
dc.identifier.other3427218en_US
dc.identifier.urihttp://hdl.handle.net/11375/12701-
dc.description.abstract<p>Since the first description of Si nanocrystals, research in this field has gone through raid progress and potential applications of Si nanocrystals have been established. There are several methods applicable to the fabrication of Si nanocrystals with one of the most used being ion implantation followed by thermal annealing. Two types of thermal annealing are available for use: furnace annealing (FA) for several hours, normally in an N<sub>2</sub> atmosphere; and rapid thermal annealing (RTA) for a short time (less than a few minutes), again in an inert atmosphere such as N<sub>2</sub>. The formation of the nanocrystals then proceeds with decomposition, segregation, diffusion, nucleation, aggregation, growth and crystallization. This formation requires temperatures in excess of 1000<sup>o</sup> C such that noticeable photoluminescence may be observed. This thesis explores the fabrication of Si nanocrystals using the McMaster ion implanter and subsequent RTA. The implantation conditions required to form luminescent nanocrystals are determined. For example, for an implantation energy of 10 KeV a minimum dose of 1.5 10<sup>16</sup> ions cm<sup>-2</sup> is required. The relationship between luminescent intensity and post-implantation annealing is also explored. An optimum annealing temperature of 1100<sup>o</sup>C is found. For the first time to the author’s knowledge, a study of the effects of thin film thickness on luminescent intensity is conducted. The major conclusions of this thesis are i) a specific thickness of oxide layer has the maximum PL for a fixed implantation energy and implantation dose, ii) PL intensity is inversely proportional with measuring temperature., iii) the type of oxidation process has a large effect on PL intensity.</p>en_US
dc.subjectPL Intensitiesen_US
dc.subjectThickness Effecten_US
dc.subjectSemiconductor and Optical Materialsen_US
dc.subjectSemiconductor and Optical Materialsen_US
dc.titleFORMATION OF SILICON NANOCRYSTALS IN SiO2 BY SILICON IMPLANTATION AND SUBSEQUENT ANNEALINGen_US
dc.typethesisen_US
dc.contributor.departmentEngineering Physicsen_US
dc.description.degreeMaster of Applied Science (MASc)en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
5.23 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue