Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/9507
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorValliant, John F.en_US
dc.contributor.authorHicks, Justin W.en_US
dc.date.accessioned2014-06-18T16:47:23Z-
dc.date.available2014-06-18T16:47:23Z-
dc.date.created2011-06-07en_US
dc.date.issued2010en_US
dc.identifier.otheropendissertations/4624en_US
dc.identifier.other5642en_US
dc.identifier.other2050678en_US
dc.identifier.urihttp://hdl.handle.net/11375/9507-
dc.description.abstract<p>To produce Tc-based radiopharmaceuticals in high effective specific activity the excess precursor ligand must be removed. A new and convenient solid-phase ligand capture method of a resin-bound Cu chelate was recently developed to remove unlabeled ligand.[1] Herein, the impact ofsize on the purification was evaluated using three welldefined resin sizes and a model chelate system, where the average capture efficiency was 89.1 ± 3.3% and loss due to non-specific binding was 23.4 ± 1.6%.</p> <p>A complementary solution-phase strategy was developed employing fluorous chemistry to remove unlabeled chelate-derivatives with less loss of product. The novel fluorous analog to the solid-phase copper chelate was synthesized in three steps (70% overall yield). Using the same model Tc(I) chelate, >99% ofthe ligand was captured by the fluorous ligand capture (FLC) method and the extent of non-specific binding was 65% lower than the solid-phase equivalent. A peptide conjugate was then used to further test the general utility ofthe FLC method with comparable ligand removal (95.1 ±0.8%) and non-specific binding (12.1 ± 1.2%).</p> <p>Attempts were made to automate the FLC method using a microfluidic device with no detrimental effect to either the radiochemical yield (4.15 ± 1.0% non-specific binding) or the efficiency of ligand capture (99.74 ± 0.04%). A second strategy involved preloading the FLC agent onto fluorous silica and capturing the excess ligand (99.85 ± 0.02%) and peptide (95± 1%) as the radiolabeling mixture was washed over the cartridge with 2.25 ± 0.55% and 33.3 ± 3.2% product lost, respectively. This approach can now be incorporated into a new generation of instant kits or an integrated microfluidic preparation of molecular imaging probes in high effective specific activity.</p>en_US
dc.subjectChemistryen_US
dc.subjectChemistryen_US
dc.titleFluorous-Phase Purification of ⁹⁹ᵐTc Radiopharmaceuticalsen_US
dc.typethesisen_US
dc.contributor.departmentChemistryen_US
dc.description.degreeMaster of Science (MS)en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
3.46 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue