Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/8956
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorMichael D. Noseworthy, Ph.Den_US
dc.contributor.advisorAlex Bain, Ph.Den_US
dc.contributor.advisorCharles Cunningham, Ph.D and Michael Patterson, Ph.Den_US
dc.contributor.authorObruchkov, Sergei I.en_US
dc.date.accessioned2014-06-18T16:44:50Z-
dc.date.available2014-06-18T16:44:50Z-
dc.date.created2011-05-15en_US
dc.date.issued2011-10en_US
dc.identifier.otheropendissertations/4121en_US
dc.identifier.other5122en_US
dc.identifier.other2014689en_US
dc.identifier.urihttp://hdl.handle.net/11375/8956-
dc.description.abstract<p>The work in this thesis deals with pre-clinical development of rapid in vivo <sup>31</sup>P mag- netic resonance spectroscopy (MRS) techniques. Current MRI literature of <sup>31</sup>P spec- troscopy presents evidence of increased concentrations of phosphomonoesters (PME), and phosphodiester (PDE) as well as inorganic phosphate concentrations in tumor tissue. Human breast cancer studies have demonstrated correlation between disease progression and both PME and PDE peaks. Furthermore, <sup>31</sup>P MRS can be used to detect, grade tumours and monitor response to chemo and radiation therapy.<br />Tumor measurements are typically static (i.e. single measurement per scan). In other experiments, on muscle for example, dynamic measures are required the purpose of which is to assess temporal function and recovery. In all <sup>31</sup>P acquisitions there are problems surrounding RF coil design, pulse sequence speed, localization and system calibration. The work presented here focused on improving all these aspects and provide easy and reliable work flow to use <sup>31</sup>P MRS in a clinical setting.<br />One of the aspects of this thesis lies in designing and construction of an RF coil that is well suited for integration with a clinical MRI breast imaging and biopsy system. The designed coil was tuned for simultaneous operation at <sup>31</sup>P (51.73 MHz) and <sup>1</sup>H (127.88MHz) Larmor frequencies. This design has advantages in the fact that complex pulse sequences with heteronuclear decoupling could be performed easily. The additional features of the coil design is that it is possible to swap it into the breast imaging system without moving the patient. Along with the designed coil, custom software was written to assist with transmit gain calibration of <sup>31</sup>P RF pulses, to ensure maximum MR signal. The automated prescan ensures easy work flow and minimizes the operator variability and patient time inside the MR scanner.<br />Another aspect of this thesis deals with rapid pulse sequence development, to further speed up the <sup>31</sup>P MRS data acquisition. Echo planar spectroscopic imaging (EPSI) with a fly–back gradient trajectory is currently one of the most reliable and robust techniques for speeding up chemical shift imaging (CSI) acquisitions. A <sup>31</sup>P EPSI sequence was written to acquire spectroscopic imaging data at 1, 2 and 2.6 cm spatial resolution and spectral bandwidth of 3125 Hz. The sequence showed an ability to speed up data acquisition up to 16 times, where SNR permits.<br />Phantom studies were used to verify the double tuned coil and EPSI sequence en- suring proper and safe operation. In vivo measurements of an exercising muscle demonstrated the ability of <sup>31</sup>P EPSI to play an important role in rapidly acquiring spatially localized <sup>31</sup>P spectroscopic data.<br />With these preclinical developments in place a clinical trial is possible using <sup>31</sup>P MRS rapidly and efficiently. Furthermore the increased usability of <sup>31</sup>P MRS provided by the tools developed in this thesis can prove to be beneficial by integrating <sup>31</sup>P MRS into existing clinical protocols.</p>en_US
dc.subjectmrien_US
dc.subjectnmren_US
dc.subjectspectroscopic imagingen_US
dc.subjectphosphorus spectroscopyen_US
dc.subjectBiological and Chemical Physicsen_US
dc.subjectBiomedical devices and instrumentationen_US
dc.subjectRadiologyen_US
dc.subjectBiological and Chemical Physicsen_US
dc.titleEcho Planar Spectroscopic Imaging and 31P In Vivo Spectroscopyen_US
dc.typethesisen_US
dc.contributor.departmentMedical Physicsen_US
dc.description.degreeDoctor of Science (PhD)en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
6.59 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue