Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/7003
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorBrash, J.L.en_US
dc.contributor.authorTian, Yuanen_US
dc.date.accessioned2014-06-18T16:37:46Z-
dc.date.available2014-06-18T16:37:46Z-
dc.date.created2010-06-24en_US
dc.date.issued1995en_US
dc.identifier.otheropendissertations/2303en_US
dc.identifier.other3251en_US
dc.identifier.other1370485en_US
dc.identifier.urihttp://hdl.handle.net/11375/7003-
dc.description.abstract<p>Novel polyurethanes bearing O-phe-pro-arg chloromethylketone (PPACK), sulphonate groups and polyethylene oxide were synthesized using block copolymerization and chain-grafting methods. The structure and the PPACK attachment mode of the PPACK-bearing polyurethane were studied by 2D NMR. The distribution of the functional groups on the corresponding biomaterial surfaces was studied by XPS. PPACK was grafted onto the polyurethane chains in such a way that its bioactivity (interactions with thrombin) was retained. The protein layers deposited from plasma onto the different polymer surfaces were studied by SDS-PAGE in conjunction with immunoblotting methods. The initiation and generation of active coagulation factors in plasma contacting different polymer surfaces were investigated by chromogenic substrate methods using specific oligopeptide substrates. The polyurethane bearing PPACK residues effectively inhibited the activation and generation of factor Xlla and thrombin in plasma contacting the surface, and prevented the clotting of the plasma. This much improved in vitro biocompatibility indicated the validity of using non-heparin antithrombin agents to prevent surface induced coagulation, and it showed that the PPACK-based polymers have potential as novel biomaterials to improve the biocompatibility of current medical devices such as small diameter vascular prostheses, hemodialyzers, stents, and catheters.</p>en_US
dc.subjectChemical Engineeringen_US
dc.subjectChemical Engineeringen_US
dc.titlePolyurethane Surfaces Bearing Immobilized Thrombin Binding Agents: Preparation and Interactions with Plasmaen_US
dc.typethesisen_US
dc.contributor.departmentChemical Engineeringen_US
dc.description.degreeDoctor of Philosophy (PhD)en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
5.74 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue