Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/6431
Title: Beta and electron dose imaging using a microspectrophotometer system and radiochromic film
Authors: Chan, Gordon H.
Advisor: Prestwich, W. V.
Department: Physics
Keywords: Physics;Physics
Publication Date: Dec-1999
Abstract: <p>A dose imaging technique of measuring the distribution of beta particles and high energy electrons, using a microspectrophotometer system and radiochromic film, has been investigated. The investigation entailed the commissioning of the microspectrophotometer and the development of a newly proposed method in film calibration. It was tested successfully by comparing the measured dose, determined using the calibration method, of films irradiated by a 32 P source, and the expected dose, determined by beta counting based on the equilibrium geometry with dose loss correction to the film substrate (20%). This method was also demonstrated to extend the usable dose range of the film. The dose imaging technique was applied to two experiments. The first experiment examines the beta depth dose distribution in Lucite, irradiated by a 32 P volume source. The experimental results were compared to Monte Carlo simulation, performed using the ITS code. The experimental distributions were found to agree closely with the Monte Carlo values up to a depth of 3 mm, but were significantly higher beyond. The second experiment examines the electron dose distribution in Lucite, irradiated by a narrow 10 MeV electron beam. The lateral experimental dose distributions were found to agree well, except at the tail end, with Monte Carlo values up to about 20 mm depth. Elsewhere, the experimental dose was found to be higher. The disagreement with Monte Carlo simulations at low doses in both experiments perhaps indicates a real discrepancy; further experimental investigations are required. The lateral spread of the beam was also investigated by determining the linear scattering power. The experimental values of the linear scattering power were found to be smaller than those quoted in the ICRU report 35 by a factor of 1.8 or less.</p>
URI: http://hdl.handle.net/11375/6431
Identifier: opendissertations/1744
3157
1365380
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File SizeFormat 
fulltext.pdf
Open Access
7.33 MBAdobe PDFView/Open
Show full item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue