Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Departments and Schools
  3. Faculty of Engineering
  4. Department of Mechanical Engineering
  5. Mechanical Engineering Publications
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/31304
Title: A comparison of nonlinear filtering methods for blackbody radiation applications in photonics
Authors: Spotts I
Brodie CH
Gadsden SA
Al-Shabi M
Collier CM
Department: Mechanical Engineering
Keywords: 40 Engineering;4001 Aerospace Engineering
Publication Date: 1-Aug-2021
Publisher: SPIE, the international society for optics and photonics
Abstract: Kalman filtering (KF) is a widely used filtering technique in highly predictable temporal-mechanical systems where system noise can be modelled with a gaussian function. Improving the signal quality during acquisition is conventionally accomplished by increasing integration time in acquisition. However, this increases the signal acquisition time in photonic systems. In high noise applications, acquisition time is low, and this post-process filtering technique can be applied to increase signal quality. This work explores the comparison of the KF, and nonlinear filtering methods to a simulated blackbody radiation signal where gaussian noise is added to mimic electrical interference. Three filters are selected for comparison on the ability to improve the root mean square error (RMSE) of a simulated measured signal with respect to a simulated actual signal. The filters that are compared in this work are the Extended Kalman Filter (EKF), the Unscented Kalman (UKF), and the Extended Sliding Innovation Filter (ESIF). The filters use a calibration temperature that the filter model uses to determine expected values. To compare the filters, the RMSE is evaluated when error is introduced to the simulation by changing the actual temperature to values equal, below, and above the calibration temperature. Two additional scenarios were considered to test filter robustness. The first scenario uses changes in model temperature occurring as a function of wavelength (i.e., temperature change mid-scan). The second scenario introduces impurities with different emission values. The ESIF demonstrated favorable performance over the other considered filters, showing promise in optical applications.
URI: http://hdl.handle.net/11375/31304
metadata.dc.identifier.doi: https://doi.org/10.1117/12.2594674
ISSN: 0277-786X
1996-756X
Appears in Collections:Mechanical Engineering Publications

Files in This Item:
File Description SizeFormat 
116-118410O.pdf
Open Access
Published version884.19 kBAdobe PDFView/Open
Show full item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue