Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Departments and Schools
  3. Faculty of Engineering
  4. Department of Mechanical Engineering
  5. Mechanical Engineering Publications
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/31101
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLourenssen K-
dc.contributor.authorWilliams J-
dc.contributor.authorAhmadpour F-
dc.contributor.authorClemmer R-
dc.contributor.authorGadsden SA-
dc.contributor.authorTasnim SH-
dc.date.accessioned2025-02-27T00:57:17Z-
dc.date.available2025-02-27T00:57:17Z-
dc.date.issued2021-02-01-
dc.identifier.issn2381-6872-
dc.identifier.issn2381-6910-
dc.identifier.urihttp://hdl.handle.net/11375/31101-
dc.description.abstractThe purpose of this paper is to highlight the design, development, and testing of a low-concentration vanadium redox flow battery (VRFB). The low-cost implementation has a 7 cm × 7 cm active membrane area and an electrolyte volume of 450 mL for each positive and negative electrolyte. The electrolyte concentration is approximately 0.066 M vanadium. An H-cell for performing electrolysis with the electrolytes is developed, and the process and method for creating the electrolyte for this low-concentration implementation are described and documented. The maximum power density and energy efficiency of the battery among tests between 500 and 800 mA are 1.32 W/L and 28.51%, respectively. Results are presented in terms of polarization curves, charge/discharge cycles, and voltage, coulombic, and energy efficiencies. Adaptation of a COMSOL Multiphysics model is implemented to compare the computational performance figures and the results of our VRFB implementation. The numerical results agree with experimentation, and differences in the results can be attributed to the losses present in the experimental tests. The proposed battery and design are intended to investigate the performance and feasibility of a low-concentration VRFB. The ultimate long-term objective of this research is the development of a novel, costeffective, and safe redox flow battery using hydrogen peroxide as one of the electrolytes.-
dc.publisherASME International-
dc.subject40 Engineering-
dc.subject4017 Mechanical Engineering-
dc.subject7 Affordable and Clean Energy-
dc.titleDesign, Development, and Testing of a Low-Concentration Vanadium Redox Flow Battery-
dc.typeArticle-
dc.date.updated2025-02-27T00:57:16Z-
dc.contributor.departmentMechanical Engineering-
dc.identifier.doihttps://doi.org/10.1115/1.4046869-
Appears in Collections:Mechanical Engineering Publications

Files in This Item:
File Description SizeFormat 
035-jeecs_18_1_011007.pdf
Open Access
Published version1.64 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue