Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/27866
Title: Epitope-Targeted Strategies for Inhibiting Pathogenic Immune Complex Formation in Heparin-Induced Thrombocytopenia
Authors: Bissola, Anna-Lise
Advisor: Nazy, Ishac
Department: Biochemistry and Biomedical Sciences
Publication Date: Nov-2022
Abstract: Heparin-induced thrombocytopenia (HIT) is an immune-mediated adverse drug reaction to the anticoagulant heparin.1,2 HIT is characterized by pathogenic antibodies that form immune complexes with platelet factor 4 (PF4) and heparin, which can cause platelet activation and thrombosis.1,3-6 Prompt diagnosis is crucial because HIT patients experience a 5-10% daily increased risk of thrombotic episodes, which are fatal in up to 30% of patients.2,6-10 The immune response in HIT is polyspecific, resulting in the production of anti-PF4/heparin antibodies that either can (pathogenic) and/or cannot (non-pathogenic) activate platelets.10-12 Differentiating between pathogenic and non-pathogenic antibodies remains a significant diagnostic challenge in HIT, exacerbated by the low specificity and limited availability of current laboratory assays.10,14,15 Previously it was shown that platelet-activating immune complexes form when pathogenic antibodies bind PF4 at a localized region that is distinct from non-pathogenic antibodies.13 In this work, high affinity inhibitors of pathogenic anti-PF4/heparin antibodies were designed using a murine monoclonal antibody (named KKO) that binds to a region on PF4 overlapping with pathogenic antibodies.16 These inhibitors were used to develop a novel diagnostic assay that can detect pathogenic antibodies with improved specificity compared to most standard tests for HIT (specificity ~50-70%).2,15 Enzyme immunoassays (EIAs) are widely used for HIT diagnosis, but have high false-positive rates because they cannot differentiate between pathogenic and non-pathogenic antibodies.10,14,15 This study found that incorporating inhibitors to block clinically significant antibody binding sites on PF4 improved the specificity (90%) of a diagnostic EIA for HIT without sacrificing sensitivity (90-100%). Unlike most high-sensitivity and -specificity diagnostic tests for HIT, such as platelet-activation assays, this EIA can also be performed with technical ease in non-specialized laboratories.
URI: http://hdl.handle.net/11375/27866
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File Description SizeFormat 
Bissola_AnnaLise_2022Aug_MSc_Biochemistry.pdf
Access is allowed from: 2023-08-31
2.79 MBAdobe PDFView/Open
Show full item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue