Title: | Surface and Subsurface Analyses of Metal-on-Polyethylene Total Hip Replacement Retrievals |
Authors: | Vuong, Vicky Pettersson, Maria Persson, Cecilia Larsson, Sune Grandfield, Kathryn Engqvist, Håkan |
Department: | Materials Science and Engineering |
Keywords: | tribology;total hip joint replacement;electron microscopy |
Publication Date: | May-2016 |
Publisher: | Springer |
Citation: | Vuong, V., Pettersson, M., Persson, C. et al. Surface and Subsurface Analyses of Metal-on-Polyethylene Total Hip Replacement Retrievals. Ann Biomed Eng 44, 1685–1697 (2016). https://doi.org/10.1007/s10439-015-1462-9 |
Abstract: | Metal-on-polyethylene (MoP) articulations are one of the most reliable implanted hip prostheses. Unfortunately, long-term failure remains an obstacle to the service life. There is a lack of higher resolution research investigating the metallic surface component of MoP hip implants. This study investigates the surface and subsurface features of metallic cobalt chromium molybdenum alloy (CoCrMo) femoral head components from failed MoP retrievals. Unused prostheses were used for comparison to differentiate between wear-induced defects and imperfections incurred during implant manufacturing. The predominant scratch morphology observed on the non-implanted references was shallow and linear, whereas the scratches on the retrievals consisted of largely nonlinear, irregular scratches of varying depth (up to 150 nm in retrievals and up to 60 nm in reference samples). Characteristic hard phases were observed on the surface and subsurface material of the cast samples. Across all samples, a 100-400 nm thick nanocrystalline layer was visible in the immediate subsurface microstructure. Although observation of the nanocrystalline layer has been reported in metal-on-metal articulations, its presence in MoP retrievals and unimplanted prostheses has not been extensively examined. The results suggest that manufacturing-induced surface and subsurface microstructural features are present in MoP hip prostheses prior to implantation and naturally, these imperfections may influence the in vivo wear processes after implantation. |
URI: | http://hdl.handle.net/11375/27541 |
ISSN: | 10.1007/s10439-015-1462-9 |
Other Identifiers: | 10.1007/s10439-015-1462-9 |
Appears in Collections: | Materials Science and Engineering Publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Vuong-ABME-2016.pdf | 733.67 kB | Adobe PDF | View/Open |
Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.