Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/27533
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorNikolova, Natalia K.-
dc.contributor.advisorBandler, John W.-
dc.contributor.authorDaniel, Tajik-
dc.date.accessioned2022-05-10T14:49:48Z-
dc.date.available2022-05-10T14:49:48Z-
dc.date.issued2022-
dc.identifier.urihttp://hdl.handle.net/11375/27533-
dc.description.abstractMicrowave imaging finds numerous applications involving optically obscured targets. One particular area is breast cancer detection, since microwave technology promises fast low-cost image reconstruction without the use of harmful radiation typical of X-ray mammography. However, the success of microwave imaging is hindered by a critical issue, the complex nature of near-field electromagnetic scattering in tissue. To overcome this, specialized image reconstruction algorithms alongside sensitive measurement hardware are required. In this work, real-time near-field microwave imaging algorithms known as quantitative microwave holography and scattered power mapping are explored. They are experimentally demonstrated to identify potential tumor regions in tissue phantoms. Alongside this development, quality control techniques for evaluating microwave hardware are also described. Two new methods for improving the image reconstruction quality are also presented. First, a novel technique, which combines two commonly used mathematical approximations of scattering (the Born and Rytov approximations), is demonstrated yielding improved image reconstructions due to the complimentary nature of the approximations. Second, a range migration algorithm is introduced which enables near-field refocusing of a point-spread function (PSF), which is critical for algorithms that rely on measured PSFs to perform image reconstruction.en_US
dc.language.isoenen_US
dc.subjectholographyen_US
dc.subjectbreast canceren_US
dc.subjectimagingen_US
dc.subjectmicrowaveen_US
dc.subjectquantitative microwave holographyen_US
dc.subjectphantomen_US
dc.subjectBornen_US
dc.subjectRytoven_US
dc.subjectfilteringen_US
dc.subjectinverse problemsen_US
dc.subjectnear fielden_US
dc.subjectrange migrationen_US
dc.subjectsynthetic aperture radar (SAR)en_US
dc.titleADVANCES IN REAL-TIME QUANTITATIVE NEAR-FIELD MICROWAVE IMAGING FOR BREAST CANCER DETECTIONen_US
dc.title.alternativeQUANTITATIVE MICROWAVE IMAGING FOR BREAST CANCER DETECTIONen_US
dc.typeThesisen_US
dc.contributor.departmentElectrical and Computer Engineeringen_US
dc.description.degreetypeThesisen_US
dc.description.degreeDoctor of Philosophy (PhD)en_US
dc.description.layabstractBreast cancer remains as one of the highest causes of cancer-related deaths in women in Canada. Though X-ray mammography remains the gold standard for regular breast cancer screening, its use of harmful radiation, painful breast compression, and radiologist dependent evaluation remain as detracting factors for its use. Over the past 40 years, researchers have been exploring the use of microwave technology in place of X-ray mammography. Microwave radiation, used at power levels similar to that of a cellphone, has been demonstrated successfully in simulations of breast scans. However, in experimental evaluations with breast phantoms, the complex scattering path of the radiation through tissue complicates image reconstruction. In this thesis, methods of improving the accuracy of microwave algorithms are explored, alongside new breast phantom structures that replicate well the electrical properties of tissue. The results of this work demonstrate the flexibility of microwave imaging, and the adversities that still need to be overcome for it to begin seeing clinical use.en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File Description SizeFormat 
tajik_daniel_2022april_phd.pdf
Open Access
Daniel Tajik PhD Thesis20.53 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue