Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Departments and Schools
  3. Faculty Publications (via McMaster Experts)
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/26543
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAndrey DO-
dc.contributor.authorCohen P-
dc.contributor.authorMeyer B-
dc.contributor.authorTorriani G-
dc.contributor.authorYerly S-
dc.contributor.authorMazza L-
dc.contributor.authorCalame A-
dc.contributor.authorArm-Vernez I-
dc.contributor.authorGuessous I-
dc.contributor.authorStringhini S-
dc.contributor.authorRoux-Lombard P-
dc.contributor.authorFontao L-
dc.contributor.authorAgoritsas T-
dc.contributor.authorStirnemann J-
dc.contributor.authorReny J-L-
dc.contributor.authorSiegrist C-A-
dc.contributor.authorEckerle I-
dc.contributor.authorKaiser L-
dc.contributor.authorVuilleumier N-
dc.date.accessioned2021-06-09T15:10:06Z-
dc.date.available2021-06-09T15:10:06Z-
dc.date.issued2020-07-24-
dc.identifier.issn2077-0383-
dc.identifier.issn2077-0383-
dc.identifier.urihttp://hdl.handle.net/11375/26543-
dc.description.abstract<jats:p>Background: Comparative data of SARS-CoV-2 IgM/IgG serology rapid diagnostic tests (RDTs) is scarce. We thus performed a head-to-head comparison of three RDTs. Methods: In this unmatched case-control study, blood samples from 41 RT-PCR-confirmed COVID-19 cases and 50 negative controls were studied. The diagnostic accuracy of three commercially available COVID-19 RDTs: NTBIO (RDT-A), Orient-Gene (RDT-B), and MEDsan (RDT-C), against both a recombinant spike-expressing immunofluorescence assay (rIFA) and Euroimmun IgG ELISA, was assessed. RDT results concordant with the reference methods, and between whole blood and plasma, were established by the Kendall coefficient. Results: COVID-19 cases’ median time from RT-PCR to serology was 22 days (interquartile range (IQR) 13–31 days). Whole-blood IgG detection with RDT-A, -B, and -C showed 0.93, 0.83, and 0.98 concordance with rIFA. Against rIFA, RDT-A sensitivity (SN) was 92% (95% CI: 78–98) and specificity (SP) 100% (95% CI: 91–100), RDT-B showed 87% SN (95% CI: 72–95) and 98% SP (95% CI: 88–100), and RDT-C 100% SN (95% CI: 88–100) and 98% SP (95% CI: 88–100). Against ELISA, SN and SP were above 90% for all three RDTs. Conclusions: RDT-A and RDT-C displayed IgG detection SN and SP above 90% in whole blood. These RDTs could be considered in the absence of routine diagnostic serology facilities.</jats:p>-
dc.publisherMDPI AG-
dc.rights.uri2-
dc.subjectCOVID-19-
dc.subjectELISA-
dc.subjectIgM/IgG serology-
dc.subjectSARS-CoV-2-
dc.subjectimmunofluorescence-
dc.subjectrapid test-
dc.titleHead-to-Head Accuracy Comparison of Three Commercial COVID-19 IgM/IgG Serology Rapid Tests-
dc.typeArticle-
dc.date.updated2021-06-09T15:10:05Z-
dc.rights.licenseAttribution - CC BY-
dc.identifier.doihttps://doi.org/10.3390/jcm9082369-
Appears in Collections:Faculty Publications (via McMaster Experts)

Files in This Item:
File Description SizeFormat 
Head-to-Head Accuracy Comparison of Three Commercial COVID-19 IgMIgG Serology Rapid Tests.pdf
Open Access
Published version268.31 kBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue