Title: The Use of In Vivo X-Ray Fluorescence Measurement in the Analysis of Cadmium Toxicology
Authors: Carew, Sean
Advisor: Chettle, David R.
Department: Physics and Astronomy
Keywords: cadmium, cadmium toxicology, in vivo, in vivo x-ray, x-ray fluorescence
Publication Date: Aug-2001
Abstract: Cadmium (Cd) is a highly toxic metallic element to the human body such that prolonged occupational or environmental exposure produces renal, hepatic, pneumonic, and neurological disorders. Thus, as a consequence it is important to have a way of monitoring cadmium exposure as it has the potential to become an occupational health hazard. The primary uses of this element are in the mining and smelting industry in the manufacture of cadmium alloys and the manufacture of alkaline accumulators. Since the discovery of X-rays in 1895 by Wilhelm Conrad Roentgen, the science of X-ray analysis has become a cardinal tool in all domains of chemical identification and classification. X-ray fluorescence (XRF) has been shown to be an effectual technique for measuring trace quantities of heavy metals such as lead in various tissues within the body. This thesis stud:r elucidates a means of measuring Cadmium in bone. The study assesses the feasibility and practicality of the polarised XRF and source excited techniques. In the polarised cadmium concentration measurements, a gain in sensitivity due to improved background characteristics was perused by increasing the x-ray tube operating voltage of the system. It was found that an operating voltage of 175 kV, and a copper filter resulted in a significant gain in sensitivity for which a minimum detection limit (MDL) of 3.5 ± 1.4 ppm was determined with 3 mm of tissue equivalent overlay. Using the source-based technique, a MDL of 3.5 ± 0.2 ppm was estimated for the corresponding tissue equivalent overlay.
URI: http://hdl.handle.net/11375/24208
Appears in Collections:Digitized Open Access Dissertations and Theses

Files in This Item:
File Description SizeFormat 
Carew_Sean_2001Aug_masters.pdf
Open Access
7.59 MBAdobe PDFView/Open
Show full item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue