Please use this identifier to cite or link to this item:
http://hdl.handle.net/11375/23051
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Cotton, James S. | - |
dc.contributor.author | Nakhla, David | - |
dc.date.accessioned | 2018-06-08T14:24:39Z | - |
dc.date.available | 2018-06-08T14:24:39Z | - |
dc.date.issued | 2018 | - |
dc.identifier.uri | http://hdl.handle.net/11375/23051 | - |
dc.description.abstract | The effect of using high voltage DC and AC on the heat transfer process during the melting of a Phase Change Material (PCM) in a rectangular enclosure was studied experimentally and numerically. The experiments were conducted for two configurations: (a) a horizontal rectangular enclosure in which the initial melting process is governed by heat conduction, (b) a vertical rectangular enclosure in which the initial melting process is governed by heat convection. The level of heat transfer enhancement was quantified by using a novel experimental facility for the horizontal configuration. The experimental methodology was verified first against non-EHD melting cases and then was further expanded to include the EHD effects. The experiments showed that EHD forces can be used to enhance a conduction dominated melting up to a maximum of 8.6-fold locally and that the level of enhancement is directly related to the magnitude of the applied voltage. It was found that the main mechanism of enhancement in these cases can be attributed to the electrophoretic forces and that the role of the dielectrophoretic forces is minimal under the applied voltages. In the vertical configuration, the effect of the magnitude of the applied voltage, the applied voltage wave-form, the gravitational Rayleigh number, Stefan number and the aspect ratio of the enclosure on the heat transfer enhancement were investigated experimentally. A novel shadowgraph experimental measurement system was developed and verified against the analytical correlations of natural convection in rectangular enclosures and the non-EHD melting performance was verified against the bench mark experiments of Ho (1984). The shadowgraph system was used to measure the local heat transfer coefficient across the heat source wall (the heat exchanger surface). The local heat transfer measurements along with the melting temporal profiles were used to explain and visualize the coupling between the Electrohydrodynamics (EHD) forces and the gravitational forces. It was found that the EHD forces could still enhance the melting process even for an initially convection dominated melting process. The mechanism of enhancement was found to be a bifurcation of the initial convection cell into multiple electro-convective cells between the rows of the electrodes. The shadowgraph system was used to assess the interaction between the electrical and the gravitational forces through the visualization of these cells and quantifying their size. The EHD heat transfer enhancement factor was found to increase by the increase of the applied voltage, reaching a 1.7 fold enhancement at the lower gravitational Rayleigh number tested and 1.45 fold for the highest gravitational Rayleigh and Stefan number. The effect of the polarity of the applied voltage was tested for the different cases and it was found that there was no significant difference between the positive and the negative polarities when the magnitude of the applied voltage was below 4 kV. At higher voltages- 6kV- the negative polarities showed better level of enhancement when compared to the positive applied voltage. It was again found that the main mechanism of enhancement is attributed to charge injection from the high voltage electrodes. A scaling analysis was conducted based on the previous conclusions and the dominant mechanism of enhancement to describe the problem in non-dimensional form. An electrical Rayleigh number was introduced and its magnitude was correlated to the magnitude of the injected current. The melt volume fraction was then represented against the non-dimensional parameter (n+1)(H/W)Fo.Ste.RaE^0.25 and the melt fraction temporal profiles for the different voltages collapsed well against this parameter. Finally, a numerical analysis was conducted on the role of the dielectrophoretic forces during the melting of Octadecane and when they would become of significant importance. The results of the numerical model supported the experimental findings and suggested that a minimum of 15 kV is needed in order to realize the effect of the dielectrophoretic forces. The numerical model was used to understand the interaction between the gravitational and the dielectrophoretic forces at different ranges of both gravitational Rayleigh number and electrical Rayleigh number. The model was complemented with scaling analysis to determine the governing scales of the problem and the dielectrophoretic Rayleigh number was deduced from the study. | en_US |
dc.language.iso | en | en_US |
dc.subject | Electrohydrodynamic | en_US |
dc.subject | Phase change material | en_US |
dc.subject | Octadecane | en_US |
dc.subject | Thermal storage | en_US |
dc.subject | Heat transfer enhancement | en_US |
dc.subject | Shadowgraph | en_US |
dc.subject | Melting | en_US |
dc.subject | Numerical modelling | en_US |
dc.title | Characterization of Electrohydrodynamic (EHD) heat transfer enhancement mechanisms in melting of organic Phase Change Material (PCM) | en_US |
dc.type | Thesis | en_US |
dc.contributor.department | Mechanical Engineering | en_US |
dc.description.degreetype | Thesis | en_US |
dc.description.degree | Doctor of Philosophy (PhD) | en_US |
Appears in Collections: | Open Access Dissertations and Theses |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Nakhla_David_2018May_PhD.pdf | PhD Thesis | 12.1 MB | Adobe PDF | View/Open |
Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.