Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/22795
Title: DESIGN AND CONSTRUCTION OF A SILICON SCHOTTKY DIODE DETECTOR FOR SINGLE PROTON COUNTING AT THE MCMASTER MICROBEAM LABORATORY
Authors: Urlich, Tomas Richard
Advisor: Thompson, Jeroen
Byun, Soo Hyun
Department: Radiation Sciences (Medical Physics/Radiation Biology)
Keywords: Schotty;Microbeam;Transmission Detector
Publication Date: 2017
Abstract: Microbeams have been used for radiation biology research since their introduction in the 1950s. A goal since their inception has been to irradiate individual cells and sub-cellular components with individual charged particles. These two criteria have been simultaneously achievable only within the last decade thanks to new technologies capable of producing very thin materials. The McMaster Microbeam Laboratory wishes to conduct such experiments using a proton beam. However, there are presently no commercially available detectors for this application, which necessitates the need for a new detector. Following literature research, a 10 μm thin Schottky diode detector was selected as the most appropriate type of detector for the setup at McMaster. The design of the detector and detection system geometries were optimized to reduce beam scattering and broadening with the aid of TRIM and MCNP simulations. Two detectors were fully constructed. However, a stable response to radiation was not achieved. One of the detectors appeared to function as a radiation detector very briefly but this result was not reproducible. The I-V curve of the detectors proved that they functioned as expected as diodes. However, without a radiation response no further characterization could be completed. Although problem solving efforts to overcome this issue were unsuccessful, a large silicon dopant concentration is suspected to be a possible cause.
URI: http://hdl.handle.net/11375/22795
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File Description SizeFormat 
Urlich_Tomas_R_201709_MSc.pdf
Open Access
1.37 MBAdobe PDFView/Open
Show full item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue