Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Departments and Schools
  3. Faculty of Engineering
  4. Department of Chemical Engineering
  5. Chemical Engineering Publications
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/22240
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLaRue, Ryan-
dc.contributor.authorCobbledick, Jeffery-
dc.contributor.authorAubry, Nicholas-
dc.contributor.authorCranston, Emily-
dc.contributor.authorLatulippe, David-
dc.date.accessioned2017-10-17T17:46:48Z-
dc.date.available2017-10-17T17:46:48Z-
dc.date.issued2015-
dc.identifier.other10.1016/j.cherd.2015.10.045-
dc.identifier.urihttp://hdl.handle.net/11375/22240-
dc.description.abstractIn this work, a new microscale flocculation test (MFT) method was developed that is ideallysuited for optimizing separation performance. A critical and complicated task in wastewater treatmentis to identify the flocculation conditions that yield the optimal separation of water from suspended solid materials. The standard ‘jar test’ method is inadequate for conducting a full process optimization because a typical set-up only allows for a maximum of 6 tests to be conducted at once and fairly large volumes of materials (approximately 1 to 2 L) are needed for each individual test. The microplate-based, parallel processing format of the MFT method allows for dozens of flocculation tests to be conducted simultaneously, with each test requiring only a few millilitres of material. As a demonstration of the MFT method, ten cationic polymer flocculants were evaluated with various digestate types. The optimal separation performance, as determined by the lowest capillary suction time (CST), was found by rigorously evaluating the effect of flocculant type (including molecular weight and charge density) and dosage conditions (including total amount added and single versus staged addition). For example, the dose-dependent profiles for certain flocculants exhibited a nearly 10-fold greater decrease in CST compared to other flocculants. Process optimization in environmental separations is not trivial, but rather, is a complicated task that requires an extensive amount of experimental work for which the MFT method is ideally suited.en_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.titleThe microscale flocculation test (MFT) – a high-throughput technique for optimizing separation performanceen_US
dc.typeArticleen_US
dc.contributor.departmentChemical Engineeringen_US
Appears in Collections:Chemical Engineering Publications

Files in This Item:
File Description SizeFormat 
The microscale flocculation test (MFT) - a high-throughput technique for optimizing separation performance.pdf
Open Access
4.52 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue