Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Digitized Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/21885
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorChing, Chan Y.-
dc.contributor.advisorEwing, Dan-
dc.contributor.authorWang, Hongbing-
dc.date.accessioned2017-08-23T19:20:55Z-
dc.date.available2017-08-23T19:20:55Z-
dc.date.issued2005-01-
dc.identifier.urihttp://hdl.handle.net/11375/21885-
dc.description.abstract<p> A virtual impactor type dust flow concentrator was developed and an experimental investigation was performed to characterize the hydraulic and particulate matter (PM) separation performance of the device. In particular, the pressure drop characteristics, the ratio of the flow through the two branches, and the PM concentration in the minor and main branch of the flow concentrator were evaluated using experiments on a diesel exhaust rig and an air rig. Tests were performed to examine the effect of the inlet flow Reynolds number, the inlet tube lip position relative to the concentration probe, and the flow distribution between the minor and main branches. Numerical simulations were also performed for a simplified concentrator geometry to examine the flow streamlines and pressure drop. The results showed that the ratio of the concentration in the minor and main flow branches changed as the flow rate in these branches changed, reaching a maximum at a minor flow ratio that depended on the lip position. It was observed the difference of the particulate matter concentration in the minor and main branch was greater for higher inlet Reynolds number. For example, the concentration ratio increased 50% as the Reynolds number increased from 2,200 to 25,700. A similar result was observed when the inlet tube lip was moved further into the concentration body. The pressure losses seem to be mainly caused by the changes in flow directions and the change in the cross sectional areas.</p>en_US
dc.language.isoen_USen_US
dc.subjectcharacterization, virtual impactor, type dust, flow concentrator, hydraulic, matter, pressure drop, Reynolds numberen_US
dc.titleDevelopment and Characterization of a Virtual Impactor Type Dust Flow Concentratoren_US
dc.typeThesisen_US
dc.contributor.departmentMechanical Engineeringen_US
dc.description.degreetypeThesisen_US
dc.description.degreeMaster of Applied Science (MASc)en_US
Appears in Collections:Digitized Open Access Dissertations and Theses

Files in This Item:
File Description SizeFormat 
Wang_Hongbing_2005Jan_Masters..pdf
Open Access
4.48 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue