Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/20631
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorMacDermid, Joy-
dc.contributor.authorNazari, Goris-
dc.date.accessioned2016-10-05T19:21:31Z-
dc.date.available2016-10-05T19:21:31Z-
dc.date.issued2016-
dc.identifier.urihttp://hdl.handle.net/11375/20631-
dc.description.abstractTechnological innovations have lead to the development of Wearable Physiological Monitoring devices, that have enabled researchers and clinicians in real-time monitoring of physiologic function within a field setting. However, it is important to establish the psychometric properties of a device prior to its utilization. A systematic review was conducted to provide a summary and appraise the quality of the literature on psychometric parameters of Zephyr Bioharness and Fitbit devices. Based on this review, we addressed the current gaps in the literature regarding the reliability parameters of Zephyr Bioharness and Fitbit Charge devices, and established the validity and agreement properties of Fitbit Charge device. For our systematic review, we searched the Google Scholar and PubMed databases to identify articles. To establish the reliability, validity and agreement parameters of Zephyr Bioharness and Fitbit Charge devices, a convenience and snowball sampling approaches were used to recruit sixty participants (30 females) from university student, staff, faculty population, and MacSeniors Community Program at McMaster University. The performance of Zephyr and Fitbit devices were assessed throughout three phases; rest, Modified Canadian Aerobic Fitness Test and recovery. In our study, at rest, inter-session average heart rate (beats/min.) ICCs (SEM) for Zephyr and Fitbit ranged from 0.90 – 0.94 (1.73 – 2.37) and 0.88 – 0.94 (1.83 – 2.67) respectively. At mCAFT, the Zephyr ICCs (SEM) ranged from 0.91 – 0.97 (3.12 – 4.64) and 0.85 – 0.98 (3.28 – 4.88) for the Fitbit. Throughout the recovery, the ICCs (SEM) ranged from 0.93 – 0.97 (2.65 – 4.66) and 0.76 – 0.91 (3.17 – 4.67) for Zephyr and Fitbit devices respectively. Pearson’s correlation coefficients and (Mean differences) for heart rate variable were 0.97 – 0.99 (-0.60 – 0.02) at Rest, 0.89 – 0.99 (13.51 – 0.62) at submaximal testing and 0.70 – 0.84 (-0.54 – 2.52) throughout recovery. The average agreement bias of heart rate in pair-wise device comparison indicated mean differences of -0.20, 4.00 and 1.00 at rest, sub-maximal testing and recovery respectively. We identified fair to very good quality evidence from 14 studies. The Zephyr Bioharness and Fitbit Charge devices demonstrated excellent reliability measures, and the Fitbit Charge device heart rate variable demonstrated strong to very strong correlations when concurrently compared with Zephyr, and provided valuable information regarding its interchangeable use in a sample of sixty healthy male and female participants of various age groups during a resting, standardized submaximal fitness and recovery phases.en_US
dc.language.isoenen_US
dc.subjectReliability, Validity, Agreement, Zephyr Bioharness, Fitbit Chargeen_US
dc.titlePsychometric Parameters of Zephyr Bioharness & Fitbit Chargeen_US
dc.typeThesisen_US
dc.contributor.departmentRehabilitation Scienceen_US
dc.description.degreetypeThesisen_US
dc.description.degreeMaster of Science (MSc)en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File Description SizeFormat 
Nazari_Goris_finalsubmission2016August_MSc.pdf.pdf
Open Access
2.63 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue