Title: Portable Heart Rate Monitor Feasibility Study
Authors: Tzannidakis, Evangelos
Advisor: Barber, H. D.
Department: Engineering Physics
Keywords: Heart Rate Monitor;Portable Heart Rate Monitor;feasibility
Publication Date: Jan-1978
Abstract: <p> It is well known that heart rate is an important physiological parameter. In some cases, continuous monitoring of active subjects is desireable. </p> <p> The report focuses on the feasibility of a miniaturized, portable heart rate monitor. Good artifact rejections, low power consumption small size and ease of use are of primary importance in such design. In order to keep size as low as possible a single cell (1 .5 V) supply voltage is used. </p> <p> A LED - phototransistor type of transducer was chosen for its good artifact rejection and simplicity of application. The transducer clips on the subject's earlobe. Light transmitted through the earlobe is amplitude modulated by the heart (blood) pulses and detected by the phototransistor thus providing electrical signal. </p> <p> In order to keep current drain low, the LED was powered by ~ 1% duty cycle pulses. The rest of the system was designed to comply with the requirements of the transducer. The detected train of pulses were preamplified and the original modulating waveform (heart pulse) reconstructed by a "sample and hold" circuit. The reconstructed signal was amplified by a narrow-band-pass amplifier filter. </p> <p> An astable and two monostable multivibrators perform the necessary timing. Two integrated circuits were also employed: a voltage regulator, to provide stable reference voltages where needed and the output amplifier filter, providing the bulk of the gain. </p> <p> A working prototype was built and suggests that a personalized heart rate monitor is quite feasible. The whole circuit can be integrated, with the exception of few capacitors and perhaps some trimming potentiometers. </p>
Description: One of two project reports. The other is designated PART A: McMASTER (ON-CAMPUS) PROJECT
URI: http://hdl.handle.net/11375/20389
Appears in Collections:Digitized Open Access Dissertations and Theses

Files in This Item:
File Description SizeFormat 
Tzannidakis_Evangelos_1978Jan_Masters.pdf
Open Access
1.87 MBAdobe PDFView/Open
Show full item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue