Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/20170
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorGarside, B. K.-
dc.contributor.authorSinclair, William John-
dc.date.accessioned2016-08-19T12:01:34Z-
dc.date.available2016-08-19T12:01:34Z-
dc.date.issued1980-03-
dc.identifier.urihttp://hdl.handle.net/11375/20170-
dc.descriptionThis is Part A.en_US
dc.description.abstract<p> The equipment necessary to measure the loss in an optical fibre has been constructed. The details of the design and the results of testing the equipment are given. This equipment was designed to measure the loss induced in fibres by ionizing radiation, but can also be used to measure undamaged samples. A "dual-beam" system is used to increase the accuracy of the equipment.</p> <p> The equipment will measure the spectral attenuation of an optical fibre to an accuracy of ±1 dB/km between .9 and 1.65 μm if the fibre is at least 175m long and has an attenuation of less than 115 dB/km. Simple modifications to the equipment would reduce the sample length required for ±1 dB/km accuracy to 60 m.</p> <p> The minimum sample length is determined by the accuracy with which samples can be connected into the system. The maximum sample attenuation is determined by the signal to noise ratio. Methods of increasing the signal to noise ratio and the sample connection accuracy are discussed. Calculations based on the suggested improvements show that the sample length can be reduced to 45 m and the maximum attenuation increased to 750 dB/km for ±1 dB/km accuracy. The use of a testing method which does not require removal of the sample could give ±1 dB/km accuracy for 10 m samples.</p> <p> The operating and adjustment procedures for the equipment are given in the appendices to this report.</p>en_US
dc.language.isoen_USen_US
dc.subjectmeasurement, loss, optical fibres, ionizing radiation, signalen_US
dc.titleMeasurement of the Loss in Optical Fibresen_US
dc.typeThesisen_US
dc.contributor.departmentEngineering Physicsen_US
dc.description.degreetypeThesisen_US
dc.description.degreeMaster of Engineering (MEngr)en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File Description SizeFormat 
Sinclair_William_J._1980Mar_Masters..pdf
Open Access
2.42 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue