Title: Reactivity Meter Analysis of Rod-Drop Experiments in Zed-2
Authors: Moniz, Manuel
Advisor: Jones, R.T.
Department: Engineering Physics
Keywords: Reactivity;Rod-Drop;Zed-2;point kinetics
Publication Date: Sep-1975
Abstract: <p> A reactivity meter code based on point kinetics was developed. Rod-drop experiments performed in the ZED-2 reactor tested the code for various detector and rod-drop positions. A delayed neutron hold-up effect was observed whenever a rod was dropped close to a detector. A better understanding of this effect was obtained through a theoretical analysis of the pertinent experiments. The three-dimensional kinetics code, CERBERUS, was used for the theoretical analysis. </p>
Description: One of two project reports. The other one is designated PART A: McMASTER (ON-CAMPUS) PROJECT
URI: http://hdl.handle.net/11375/19795
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File Description SizeFormat 
Moniz_M_1975Sept_Masters.pdf
Open Access
22.24 MBAdobe PDFView/Open
Show full item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue