Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/19041
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorByun, Soo-Hyun-
dc.contributor.authorOrchard, Gloria M.-
dc.date.accessioned2016-04-06T13:50:58Z-
dc.date.available2016-04-06T13:50:58Z-
dc.date.issued2010-12-
dc.identifier.urihttp://hdl.handle.net/11375/19041-
dc.description.abstract<p> In experimental microdosimetry one of the goals is to measure the absorbed dose in microscopic volumes of tissue. The traditional spherical tissue-equivalent proportional counter (TEPC) is the most common detector currently used for microdosimetry. A new microdosimetric detector based on a thick gas electron multiplier (THGEM) was developed. To investigate the feasibility of the THGEM type detector for microdosimetry, a prototype detector was designed and manufactured. The THGEM detector is robust, easy to manufacture and is cost effective. The THGEM foil is composed of a thin FR4-epoxy insulator coated with copper on both sides. The THGEM contains 32 holes each with a diameter of 0.35 mm and pitch of 0.64 mm. The sensitive volume of the detector is a right cylinder with a diameter of ~5 mm and height of ~5 mm and is located in the center of the detector. Systematic tests were conducted at the McMaster Accelerator Laboratory to investigate its overall performance. A neutron-gamma ray radiation field was generated using the 7Li(p,n) reaction. The detector was operated at low bias voltages initially to test the stability and then the relative multiplication gain was measured as a function of the operating high voltage. The detector performance was observed with different THGEM insulator thicknesses ranging from 0.12 mm to 1.48 mm. The multiplication gain was assessed and both neutron and gamma-ray radiation was detected by the THGEM detector. The spectra obtained with the THGEM detector were analyzed and compared to the data collected with the standard spherical TEPC. The investigations provided information about the THGEM detector operation for microdosimetry and the THGEM microdosimetric spectra observed are comparable to the standard TEPC data.</p>en_US
dc.language.isoen_USen_US
dc.subjectthick, gas, electron, multiplier, microdosimetry, diameter, volume, dataen_US
dc.titleDevelopment of a Thick Gas Electron Multiplier Detector for Microdosimetryen_US
dc.typeThesisen_US
dc.contributor.departmentMedical Physicsen_US
dc.description.degreetypeThesisen_US
dc.description.degreeDoctor of Philosophy (PhD)en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File Description SizeFormat 
Orchard_Gloria_M._2010Dec_Ph.D..pdf
Open Access
5.59 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue