Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/18242
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorSirouspour, Shahin-
dc.contributor.authorEmami Abarghouei, Shadi-
dc.date.accessioned2015-09-25T19:05:07Z-
dc.date.available2015-09-25T19:05:07Z-
dc.date.issued2015-11-
dc.identifier.urihttp://hdl.handle.net/11375/18242-
dc.description.abstractThis thesis is concerned with model-based non-rigid registration of single-modality magnetic resonance images of compressed and uncompressed breast tissue in breast cancer diagnostic/interventional imaging. First, a volumetric registration algorithm is developed which solves the registration as a state estimation problem. Using a static deformation model. To reduce computations, the similarity measure is calculated at some specific points called control points. These control points can be from a low resolution image grid or any irregular image grid. Our numerical analysis has shown that control points placed in the area without much information; i.e with small or no changes in image intensity, yield negligible deformation. Therefore, the selection of the control points can significantly impact the accuracy and computation complexity of the registration algorithms. An extension of the speeded up robust features (SURF) to 3D is proposed for enhanced selection of the control points in deformable image registration. The impact of this new control point selection method on the performance of the registration algorithm is analyzed by comparing it to the case where regular grid control points are used. The results show that the number of control points could be reduced by a factor of ten with new selection methodology without sacrificing performance. Second image registration method is proposed in which, based on a segmented pre-operative image, a deformation model of the breast tissue is developed and discretized in the spatial domain using the method of finite elements. The compression of the preoperative image is modeled by applying smooth forces on the surface of the breast where compression plates are placed. Image registration is accomplished by formulating and solving an optimization problem. The cost function is a similarity measure between the deformed preoperative image and intra-operative image computed at some control point and the decision variables are the tissue interaction forces.en_US
dc.language.isoenen_US
dc.subjectImage Registrationen_US
dc.subjectDeformable Modelen_US
dc.subjectFeature Extractionen_US
dc.subjectFinite Element Modelen_US
dc.titleMODEL-BASED DEFORMABLE REGISTRATION OF MRI BREAST IMAGES WITH ENHANCED FEATURE SELECTIONen_US
dc.typeThesisen_US
dc.contributor.departmentBiomedical Engineeringen_US
dc.description.degreetypeThesisen_US
dc.description.degreeMaster of Applied Science (MASc)en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File Description SizeFormat 
EmamiAbarghouei_Shadi_2015Sep_MASc.pdf
Open Access
Main articale2.1 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue