Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/17511
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorWoods, D. R.-
dc.contributor.authorBurrill, Kenneth A.-
dc.date.accessioned2015-06-10T19:45:19Z-
dc.date.available2015-06-10T19:45:19Z-
dc.date.issued1967-05-
dc.identifier.urihttp://hdl.handle.net/11375/17511-
dc.description.abstract<p> The separation of a mixture of carbon tetrachloride in water was studied in a 2 inch diameter glass hydrocyclone. First, the effect of a mixing valve and of oil/water ratio on the volume/surface diameter of the dispersion in the feed to the hydrocyclone was studied using a statistical experiment design. Secondly, the effect of feed drop size distribution, oil/water ratio, and overflow/underflow split on the separation in the hydrocyclone was determined, again using a statistical experiment design. In both designs, five levels of each variable were studied. Flow rate, design shape, and temperature were kept constant. The range of variables was: </p> <p> 1. Mixing Value Pressure Drop 17.95 to 88.25 mm. Hg </p> <p> 2. Oil/Water Ratio 0.132 to 0.211 </p> <p> 3. Overflow/Underflow Split 4/1 to 8/1 </p> <p> From the first part of the work it was found that oil/water ratio had no significant effect on the volume/surface diameter, and that there was a linear relationship between the volume/surface diameter and mixing valve pressure drop. </p> <p> From the second part of the work it was found that volume split had most significant effect on hydrocyclone separation for the range of variables studied. The oil/water ratio had the next most significant effect on separation, and finally, drop size distribution was also found to be significant, but was the least important of the three variables. The interactions of the variables were no significant. The hydrocyclone separation could be predicted. The prediction of the overflow drop-size distribution agreed very well with the distribution observed photographically. Both predictions required assumptions that short-circuit flow and drop-drop coalescence was negligible. </p>en_US
dc.language.isoenen_US
dc.subjectchemical engineeringen_US
dc.subjectdrop size distributionen_US
dc.subjectfeed concentrationen_US
dc.subjectvolumeen_US
dc.subjectseparationen_US
dc.subjectimmiscibleen_US
dc.subjecthydrocycloneen_US
dc.titleThe Effect of Drop Size Distribution, Feed Concentration, and Volume Split on the Separation of Two Immiscible Liquids in a Hydrocyclone.en_US
dc.contributor.departmentChemical Engineeringen_US
dc.description.degreetypeThesisen_US
dc.description.degreeMaster of Engineering (ME)en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File Description SizeFormat 
Burrill_Kenneth_A_1967May_MEng.pdf
Open Access
14.7 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue