Skip navigation
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Publication Date
    • Author
    • Title
    • Subject
    • Department
  • Sign on to:
    • My MacSphere
    • Receive email
      updates
    • Edit Profile


McMaster University Home Page
  1. MacSphere
  2. Open Access Dissertations and Theses Community
  3. Open Access Dissertations and Theses
Please use this identifier to cite or link to this item: http://hdl.handle.net/11375/16683
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorMcGee, W.F.-
dc.contributor.advisorGarside-
dc.contributor.advisorBryden, B.-
dc.contributor.authorBrown, Stephen J.G.-
dc.date.accessioned2015-01-28T15:09:00Z-
dc.date.available2015-01-28T15:09:00Z-
dc.date.issued1973-05-
dc.identifier.urihttp://hdl.handle.net/11375/16683-
dc.descriptionThis thesis is in two parts. Part A is about the study of the LD-4 Regenerator and Part B is about Lasing Action. Both are essential for the completion of Stephen Brown's Master of Engineering Degree.en_US
dc.description.abstract<p>The switching mechanism of the LD-4 regenerator is studied by applying triangular signals with variable slope and phasing with respect to the sampling pulse in order to investigate their effect on the output signal voltage. Experimental results are obtained in the form of finite sampling crosshairs. These represent the family of input signals that produce all output between the 0 and 1 state. In effect they characterize PST input signals at the N^(th) regenerator to the eventual PST signals at the N+1^(th) regenerator input. </p><p> An attempt is a 1 so made to correlate the experimenta 1 data with either a constant voltage or constant charge sensitivity model in order to understand the mechanism of sampling. </p><p>Results of a detailed investigation of the time-dependence of the stimulated emission from electron-beam pumped CdS platelets are reported. Unlike lower threshold platelets previously reported (1), the platelet examined here exhibits rapid tuning with time of the stimulated emission to longer wavelength. The rate of this frequency tuning canpares favourably with the value reported by Shewchun et al (2) for CdS crystals many times thicker and with a higher threshold than the one measured in this report. Furthermore, there is a temporal variation of the angular position of the spatial mode. This temporal variation or angular tuning rate was compared with angular tuning data reported for GaAs and CdSe as well as with the theory that predicts such tuning in these crystals (3). </p>en_US
dc.language.isoenen_US
dc.subjectsignal voltageen_US
dc.subjectPST input signalsen_US
dc.subjectcharge sensitivity modelen_US
dc.subjectsampling mechanismen_US
dc.titleA Study of the "LD-4 Regenerator" Sampling Mechanism and "Lasing Action" in High Threshold Electron Beam Pumped CdS Plateletsen_US
dc.typeThesisen_US
dc.contributor.departmentEngineering Physicsen_US
dc.description.degreetypeThesisen_US
dc.description.degreeMaster of Engineering (ME)en_US
Appears in Collections:Open Access Dissertations and Theses

Files in This Item:
File Description SizeFormat 
Stephen Brown COMPLETE.pdf
Open Access
Main Thesis2.59 MBAdobe PDFView/Open
Show simple item record Statistics


Items in MacSphere are protected by copyright, with all rights reserved, unless otherwise indicated.

Sherman Centre for Digital Scholarship     McMaster University Libraries
©2022 McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8 | 905-525-9140 | Contact Us | Terms of Use & Privacy Policy | Feedback

Report Accessibility Issue